Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The International Dysphagia Diet Standardization Initiative (IDDSI) proposed the flow test (FT) as a simple method for measuring the viscosity of thickened liquids. However, the FT specifies the use of a particular syringe type (BD-Slip), which is unfortunately not easily available in Japan. Therefore, the current study primarily aimed to investigate the effects of the internal syringe shape on IDDSI FT and identify the most suitable syringe available in Japan for xanthan gum-based thickened liquids. Accordingly, four syringes, namely, Luer slip tip, Luer-Lok tip, TERUMO, and NIPRO syringes, were used to examine FT value with water and nine different water viscosity levels. The correlation and systematic errors on residual FT values between the BD-Slip syringe and the other three syringes were analyzed. The two-dimensional internal shapes of the four syringes were measured using industrial computed tomography (CT) scanning. Based on the results of our FT, TERUMO had the smallest error range among the three syringes, without systematic errors. On a CT scan, three of five tip-shape parameters showed the smallest difference between BD-Slip and TERUMO syringe. Therefore, TERUMO had the smallest FT error range compared with that in BD-Slip tip syringe, indicating that TERUMO could be used as a substitute for BD-Slip when performing IDDSI FT with xanthan gum-based thickened water in Japan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jtxs.12640 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!