Purpose: To assess the reproducibility of a manual muscle MRI segmentation method that follows a specific set of recommendations developed in our center.

Materials And Methods: Nine healthy volunteers underwent a muscle MRI examination that included a TSE T2 sequence of the thighs. Muscle segmentation was performed by three operators: an expert operator (OP1) with 3 years of experience and two radiology residents (OP2 and 3) who were both given basic segmentation instructions, whereas only OP2 underwent additional supervised training from OP1. Intra- and inter-operator Dice similarity coefficient (DSC) was calculated.

Results: OP1 showed the highest average intra-operator DSC values (0.885), whereas OP2 had higher average DSC (0.856) compared to OP3 (0.818). The highest inter-operator agreement was observed between Operators 1 and 2 (0.814) and the lowest between OP2 and OP3 (0.702). Confidence interval (CI) analysis showed that the most experienced operator also had the least variability in drawing the ROIs, whereas OP2 showed both higher intra-operator reproducibility compared to OP3 and higher inter-operator agreement with OP1. The muscles that showed the least reproducibility were the and the short head of the .

Discussion: Following specific recommendations such as these ones derived from our single-center experience leads to an overall high reproducibility of manual muscle segmentation and is helpful in improving both intra-operator and inter-operator reproducibility in less experienced operators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489167PMC
http://dx.doi.org/10.36185/2532-1900-052DOI Listing

Publication Analysis

Top Keywords

reproducibility manual
12
manual muscle
8
muscle mri
8
muscle segmentation
8
op2 higher
8
compared op3
8
inter-operator agreement
8
reproducibility
6
segmentation
5
muscle
5

Similar Publications

Background And Purpose: To develop a new test to assess the motor coordination of the upper limbs, and to investigate the test-retest and inter-rater reliability, construct validity, standard error of measurement (SEM), minimum detectable change (MDC), and the reference values.

Methods: The Upper Extremity Motor Coordination Test (UEMOCOT)was applied for 20 s, with the individual touching two targets (one right and one left) as quickly as possible, first with the hand (manual task) and then with the index finger (finger task). To test-retest reliability, the UEMOCOT was administered two times.

View Article and Find Full Text PDF

More work is needed to establish the validity of the Alternative Model of Personality Disorders (AMPD) in the Diagnostic and Statistical Manual of Mental Disorders (DSM-5). Acceptance of the AMPD as the primary model of personality disorder requires identifying neurocognitive validators of AMPD-defined personality functioning and demonstrating superiority of the AMPD over the traditional categorical model of personality disorder. It is also important to establish the utility of the AMPD in a developmental context given evidence that personality disorder emerges in adolescence.

View Article and Find Full Text PDF

Objectives: The continuous integration of artificial intelligence (AI) into clinical settings requires the development of up-to-date and robust guidelines and standard frameworks that consider the evolving challenges of AI implementation in medicine. This review evaluates the quality of these guideline and summarizes ethical frameworks, best practices, and recommendations.

Materials And Methods: The Appraisal of Guidelines, Research, and Evaluation II tool was used to assess the quality of guidelines based on 6 domains: scope and purpose, stakeholder involvement, rigor of development, clarity of presentation, applicability, and editorial independence.

View Article and Find Full Text PDF

Sensitive non-enzymatic sensing of creatinine in urine using a novel paper-based electroanalytical device.

Talanta

December 2024

Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing, China. Electronic address:

Accurate analysis of urinary creatinine levels is of great clinical significance. Non-enzymatic creatinine sensing systems (NECSs) have gained growing development because of higher stability and lower cost compared to enzymatic sensing systems. At present, there is a demand for simple approaches to develop NECSs with high sensitivity.

View Article and Find Full Text PDF

Nextflow4MS-DIAL: A Reproducible Nextflow-Based Workflow for Liquid Chromatography-Mass Spectrometry Metabolomics Data Processing.

J Am Soc Mass Spectrom

January 2025

Department of Health Outcomes and Biomedical Informatics, College of Medicine, University of Florida, Gainesville, Florida 32611, United States.

Reproducibility in untargeted metabolomics data processing remains a significant challenge due to software limitations and the complex series of steps required. To address these issues, we developed Nextflow4MS-DIAL, a reproducible workflow for liquid chromatography-mass spectrometry (LC-MS) metabolomics data processing, validated with publicly available data from MetaboLights (MTBLS733). Nextflow4MS-DIAL automates LC-MS data processing to minimize human errors from manual data handling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!