A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Four Rapid Antigen Tests for Detection of SARS-CoV-2 virus. | LitMetric

Objectives: Considering the increasing, significant burden that coronavirus disease 2019 (COVID-19) imposes on the healthcare system, the need for simple, rapid, and affordable diagnostic tests to support the existing costly and demanding polymerase chain reaction (PCR) assay becomes required. This prospective diagnostic test accuracy study aims to evaluate the performance of four different COVID-19 rapid antigen tests compared to real-time reverse transcription PCR (rRT-PCR) between June and July 2020 to determine the feasibility of integrating these tests into the diagnostic algorithm in clinical settings.

Methods: Swabs were collected from 306 patients and analyzed using rRT-PCR and antigen tests from four different providers.

Results: The antigen tests' sensitivities were 65.8%, 69.8%, 64.0%, and 64.3% for the STANDARD™ Q COVID-19 Ag test, PCL COVID-19 Ag Rapid fluorescent immunoassay (FIA) test, BIOCREDIT COVID-19 Ag test, and Sofia SARS-CoV-2 antigen FIA test, respectively. Specificity was 94.1% for PCL COVID-19 Ag Rapid test and 100% for the other three assays. All assays showed a significant negative correlation between the reference rRT-PCR Ct values and Ag test results. Besides, sensitivities of the STANDARD™ Q COVID-19 Ag test, PCL COVID-19 Ag Rapid FIA test, and BIOCREDIT COVID-19 Ag test improved to ≥ 85% after exclusion of samples with PCR Ct values > 30.

Conclusions: The high specificity of the rapid antigen tests and other parameters like simplicity, rapidity, and affordability suggest that antigen tests are likely to be helpful if integrated and interpreted appropriately in stepwise diagnostic algorithms. Given the low sensitivity of 64.0-69.8% of the antigen tests, we recommend that clinically relevant negative results undergo further testing Ag to confirm or exclude a COVID-19 diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8491111PMC
http://dx.doi.org/10.5001/omj.2021.106DOI Listing

Publication Analysis

Top Keywords

antigen tests
24
covid-19 rapid
16
covid-19 test
16
rapid antigen
12
pcl covid-19
12
fia test
12
covid-19
10
test
10
antigen
8
tests
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!