Accurate measurement of the aortic valve annulus is critical for proper valve sizing for the transcatheter aortic valve replacement (TAVR) procedure. While computed tomography angiography (CTA) is the widely-accepted standard, two-dimensional (2D) and three-dimensional(3D) transesophageal echocardiography (TEE) is commonly performed to measure the size of the aortic valve and to verify appropriate seating of prostheses. Patients undergoing TAVR between 2013-2015 were examined. 2D- and 3D-TEEmeasurements were compared to CTA taken as standard. Patients were followed for at least one year. The presence and effect of discrepancy (defined as a difference of more than 10%) between CTA and TEE measurements on survival were examined. One hundred eighty-five patients (70 men) were included. 2D- and 3D-TEE measurements underestimated the annulus size by -1.49 and -1.32 mm, respectively. Discrepancies > 10% between TEE and CTA methods in estimating the aortic annulus size were associated with a decrease in post implant survival. The peak pressure gradient across the aortic prosthesis measured one year after the implant was higher in patients with an initial discrepancy between 3D-TEE and CTA measurements. In a multivariate cox-regression model, the discrepancy between CTA and 2D-TEE readings and the smaller size of the aortic annular area were the predictors of long-term survival. Both 2D and 3D-TEE underestimate the aortic annulus measurements compared to CTA, with 2D-TEE being relatively more precise than 3D-TEE technology. The presence of a discrepancy between echocardiographic and CTA measurements of the aortic annulus is associated with a lower survival rate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8493236 | PMC |
http://dx.doi.org/10.34172/jcvtr.2021.39 | DOI Listing |
J Soc Cardiovasc Angiogr Interv
December 2024
Cardiovascular Institute, Detroit Medical Center, DMC Heart Hospital, Detroit, Michigan.
Transcatheter aortic valve repair (TAVR) presents a minimally invasive alternative to traditional surgical valve replacement, albeit not without its own set of complications. A rare complication is the infolding of the self-expanding valve, which can precipitate cardiac arrest. The estimated incidence rate of this complication stands at 1.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Medicine, Michael E DeBakey Veteran's Affairs Medical Center, Houston, Texas, USA.
Transcatheter aortic valve replacement (TAVR) has become a viable treatment option for patients with severe aortic stenosis among all risk subsets. As TAVR use becomes more prevalent and patients live longer with their transcatheter valve, an increasing number of these patients can be expected to present with ACS. Overall, there is a paucity of high-quality data detailing incidence, pathophysiology, and management of ACS in this subset.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFRen Fail
December 2025
Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China.
Background: The incidence of acute kidney injury (AKI) increases after surgical aortic valve replacement (SAVR). This study aimed to characterize the risk factors of AKI after SAVR.
Methods And Results: We conducted a retrospective registry study based on data from 299 consecutive patients undergoing SAVR.
Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!