Vacuum cooling of baked goods can deliver many advantages in terms of product quality and productivity, such as higher volumes and shorter cooling times. However, the associated high costs and the need to adjust baking protocols are of relevance and more information is needed. This paper examines the influence of two main baking protocol parameters on the quality of toast bread, i.e. oven temperature and baking time reduction. Resulting toast bread characteristics including specific bread volume, concavity, browning index, crust and crumb hardness and a-value were analysed as well as process-dependent core temperature and water loss. In order to compensate for water loss during vacuum cooling and still achieve optimal toast bread quality, a final bread core temperature of 98 °C at the end of baking gave best results, regardless of oven temperature. It was further shown that cooling time can be reduced by a factor of 10 if the baking protocol is optimally adjusted, hinting at a huge potential to increase productivity for industrial applications. In summary, it can be stated that vacuum cooling requires a tailored reduction in baking time in order to compensate for water loss from vacuum cooling while retaining sufficient structural cohesion to resist deformation of the bread.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8479013 | PMC |
http://dx.doi.org/10.1007/s13197-020-04945-x | DOI Listing |
Sensors (Basel)
December 2024
Laboratorio de Circuitos Integrados (LABIC), Departamento de Electrónica, Área de Instrumentación, Instituto de Astrofísica de Canarias (IAC), 38205 La Laguna, Tenerife, Spain.
The use of non-cryogenic certified commercial electronics for cryogenic applications may be attractive due to their cost and availability, but it also carries risks related to reliability, performance and thermal compatibility. The decision to use commercial components that are not certified for cryogenics instead of components specifically designed for such applications must be carefully weighed based on specific project needs and risk tolerances. This work presents the characterisation of an attenuator circuit at cryogenic temperatures used in a microwave kinetic inductance detector (MKID) readout system.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
Department of Mechanical Engineering & Materials Science and Engineering Program, State University of New York at Binghamton, Binghamton, New York 13902, United States.
In contrast to the traditional perspective that thermal fluctuations are insignificant in surface dynamics, here we report their influence on surface reaction dynamics. Using real-time low-energy electron microscopy imaging of NiAl(100) under both vacuum and O atmospheres, we demonstrate that transient temperature variations substantially alter the direction of atom diffusion between the surface and bulk, leading to markedly different oxidation outcomes. During heating, substantial outward diffusion of atoms from the bulk to the surface results in step growth.
View Article and Find Full Text PDFACS Nano
January 2025
School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Ultrafast thermal switches are pivotal for managing heat generated in advanced solid-state applications, including high-speed chiplets, thermo-optical modulators, and on-chip lasers. However, conventional phonon-based switches cannot meet the demand for picosecond-level response times, and existing near-field radiative thermal switches face challenges in efficiently modulating heat transfer across vacuum gaps. To overcome these limitations, we propose an ultrafast thermal switch design based on pump-driven transient polaritons in asymmetric terminals.
View Article and Find Full Text PDFRev Sci Instrum
December 2024
2nd Institute of Physics B and JARA-FIT, RWTH Aachen University, 52074 Aachen, Germany.
Low-temperature scanning tunneling spectroscopy is a key method to probe electronic and magnetic properties down to the atomic scale, but suffers from extreme vibrational sensitivity. This makes it challenging to employ closed-cycle cooling with its required pulse-type vibrational excitations, albeit this is mandatory to avoid helium losses for counteracting the continuously raising helium prices. Here, we describe a compact ultra-high vacuum scanning tunneling microscope (STM) system with an integrated primary pulse tube cooler (PTC) for closed-cycle operation.
View Article and Find Full Text PDFPhys Chem Chem Phys
December 2024
Department of Physical Chemistry, University of Chemistry and Technology, Prague Technická 5, 166 28 Praha 6, Czechia.
The cooling of water clusters through evaporation into a vacuum is studied using classical molecular dynamics with the SPC water model, and the results are compared with macroscopic theory. A simple model based on the Hertz-Knudsen equation significantly underestimates cooling rates. A modified approach that accounts for the Kelvin equation provides better results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!