Prospective evaluation of radiation dose with conventional fluoroscopic voiding cystourethrogram in pediatric patients.

J Pediatr Urol

Department of Urology, University of Pittsburgh School of Medicine, UPMC Children's Hospital of Pittsburgh, 4401 Penn Avenue, Pittsburgh, PA, 15224, USA; Department of Urology, University of California-Irvine, Children's Hospital of Orange County, 505 S Main Street, Suite 100, Orange, CA, 92868, USA.

Published: December 2021

Introduction: Skin entrance doses for voiding cystourethrogram (VCUG) have not been well characterized in the literature. Radiation exposure is measured as either dose area product (DAP) or air kerma, which estimates the effective dose, but does not accurately reflect absorbed dose at skin level.

Objective: The objective of this study was to measure the skin entrance dose during fluoroscopic VCUG study in pediatric patients using single point dosimeters.

Study Design: Pediatric patients undergoing fluoroscopic VCUG were prospectively enrolled in our study. Landauer NanoDot™OSLD dosimeters were affixed to the skin overlying the sacrum to measure skin entrance dose. The fluoroscopic unit was set to the following parameters: low dose setting, skin-to-source distance of 54 cm, pulsed fluoroscopy at 3 frames/sec.

Results: Forty-four patients with a median age of 13.6 months (IQR 3.7-42.3) were enrolled. Median fluoroscopic time was 54 s (IQR 36-72). The median values absorbed dose by dosimeter and air kerma were 0.32 mGy (IQR 0.13-0.56, range 0.01-2.9) and 0.24 mGy (IQR 0.14-0.37), respectively. There was a positive correlation between the air kerma and absorbed dose (r = 0.69, p < 0.001) and fluoroscopy time and absorbed dose mGy (r = 0.60, p < 0.001). Absorbed dose was independent of age, body mass index and body surface area (p = 0.19, p = 0.57 and p = 0.16, respectively). Median whole body effective dose was 0.04 mSv (IQR 0.02-0.7).

Discussion: Overall, the absorbed dose received by the dosimeter remained low at a median of 0.32 mGy (range 0.01-2.91). These values are remarkably low and well within the accepted radiation exposure norms. Our radiologists follow a strict protocol to reduce the overall radiation emitted during a VCUG. These measures include setting the x-ray source at a low dose mode, collimating to the smallest area possible, and using pulsed fluoroscopy at 3 frames/sec. Limitations to this study include a slight variability in technique of VCUG between different technicians and providers, for which we cannot control.

Conclusion: The radiation dose absorbed at the skin entrance and uniform whole body effective dose is low for a single VCUG when utilizing strict parameters. While newer non-ionizing technologies continue to emerge, our data is encouraging and will serve as a valuable tool when educating parents regarding radiation doses associated with a VCUG.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpurol.2021.09.010DOI Listing

Publication Analysis

Top Keywords

pediatric patients
12
skin entrance
12
air kerma
12
absorbed dose
12
dose
9
voiding cystourethrogram
8
measure skin
8
entrance dose
8
dose fluoroscopic
8
fluoroscopic vcug
8

Similar Publications

Case: A pediatric patient with focal fibrocartilaginous dysplasia (FFCD) developed angular deformity and growth arrest despite standard guided growth management. The patient underwent implant-mediated guided growth for proximal tibia varus deformity which recurred; subsequently, a physeal bar of the medial proximal tibia was diagnosed, which progressed to physeal arrest.

Conclusion: Treatment options for FFCD-associated angular deformity include observation and guided growth.

View Article and Find Full Text PDF

Objective: To examine differences in the presentation and management of concussion in younger children (aged 4-8 years) versus preadolescents (9-12 years) and identify factors that influence recovery time.

Design: Retrospective analysis of prospectively collected data.

Setting: Pediatric sports medicine and orthopedics clinic.

View Article and Find Full Text PDF

Objective: Functional MRI (fMRI) helps with the identification of eloquent cortex to assist with function preservation in patients who undergo epilepsy surgery. Language and memory tasks can even be used effectively in clinically involved pediatric patients. Most pediatric studies report on English speaking-only cohorts from English-dominant countries, yet languages other than English (LOEs) are increasingly prevalent in countries such as the US.

View Article and Find Full Text PDF

Introduction: Following liver transplantation (LT), adequate nutrition is essential, as malnutrition may contribute to slower growth in pediatric patients and put patients at risk of complications following transplant. Avoidant Restrictive Food Intake Disorder (ARFID) is an eating disorder characterized by restrictive eating patterns that compromise nutrition. Patients with ARFID may have significant difficulty meeting nutritional needs due to fear of gastrointestinal distress, making it especially difficult to manage in patients following LT.

View Article and Find Full Text PDF

Background: Pediatric solid organ transplantation is challenging due to the limited availability of suitable organs resulting in an increasing waitlist. Many pediatric transplant recipients receive organs from deceased donors, often after neurologic determination of death. Organ donation from patients on extracorporeal membrane oxygenation (ECMO) at the time of death has been described in adults, offering the potential for donation after circulatory determination of death (DCDD) with minimal ischemia time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!