A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using mass spectrometry to overcome the longstanding inaccuracy of a commercially-available clinical testosterone immunoassay. | LitMetric

Using mass spectrometry to overcome the longstanding inaccuracy of a commercially-available clinical testosterone immunoassay.

J Chromatogr B Analyt Technol Biomed Life Sci

Department of Laboratory Medicine and Pathology, University of Washington, School of Medicine, United States; Department of Medicine, University of Washington School of Medicine, United States; Kidney Research Institute, University of Washington, School of Medicine, United States. Electronic address:

Published: October 2021

Accurate measurement of testosterone is important for the diagnosis of gonadal disorders in men, women, and children. Testosterone measurement has limited accuracy at low concentrations by most commercially available immunoassays. We aimed to develop an LC-MS/MS assay to address the inaccuracy of the in-house immunoassay observed over the past decade and to replace it with the new assay. Testosterone in serum/plasma was extracted with commercial supported liquid extraction plates. Method validation was performed following the CLSI C62-A guideline. A total of 126 samples were used for method comparison between the Beckman UniCel DxI immunoassay and LC-MS/MS. Results by immunoassay were 20% lower compared with LC-MS/MS and had minimal correlation (R = 0.403) with LC-MS/MS below 100 ng/dL. When comparing specimens from the Accuracy-Based Survey from the College of American Pathologists, the newly developed assay agreed well with the CDC reference measurement procedure. In summary, immunoassay measurement of testosterone can be significantly inaccurate, especially at low concentrations. The newly developed LC-MS/MS assay provides accurate results across the entire measurable range.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589107PMC
http://dx.doi.org/10.1016/j.jchromb.2021.122969DOI Listing

Publication Analysis

Top Keywords

measurement testosterone
8
low concentrations
8
lc-ms/ms assay
8
newly developed
8
testosterone
5
immunoassay
5
lc-ms/ms
5
mass spectrometry
4
spectrometry overcome
4
overcome longstanding
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!