Background: At present, silicone oil has been widely used in vitrectomy to deal with complex fundus diseases. Usually, cataract extraction is combined with vitrectomy. However, reducing the complications of silicone oil tamponade and facilitating the secondary implantation of intraocular lens (IOL) are still an urgent problem.
Aim: To evaluate the clinical effect of vitrectomy combined with peripheral capsule preservation (PCP) in eyes with silicone oil tamponade.
Methods: This single-center retrospective analysis included 70 patients (73 eyes) who underwent vitrectomy and silicone oil tamponade combined with cataract surgery (stage I) between January 2015 and July 2019. All patients underwent selective reoperation for silicone oil extraction and IOL implantation (stage II) more than 3 mo after stage I. These patients were divided into three groups according to the different lens capsule preservation methods: 28 patients (31 eyes) in a whole capsule preserved (WCP) group, 17 (17 eyes) in a capsule absent (CA) group, and 25 (25 eyes) in a peripheral capsule preserved (PCP) group. Intraocular pressure (IOP), best-corrected visual acuity, surgery time, and other complications were recorded at each time point (1 d, 1 wk, and 1 mo after stages I and II).
Results: The IOP values were 14.9 ± 8.2 mmHg in the WCP group, 20.3 ± 13.0 mmHg in the CA group, and 14.2 ± 9.7 mmHg in the PCP group ( < 0.05) at 1 mo after stage I operation. Five eyes had IOP higher than 30 mmHg, and one eye in the WCP group appeared to have silicone oil entering the anterior chamber. There was no significant difference in IOP among the three groups at any other time point ( > 0.05). With IOL implantation, visual acuity improved significantly compared to stage I. The incidence rate of posterior capsule opacity was higher in the WCP group than in the other groups ( < 0.001). In the CA group, IOL deviation due to suture relaxation occurred in one case. There was no significant difference in the surgery time among the three groups in stage I ( = 0.618). In stage II, the surgery time of the PCP group and WCP group was significantly shorter than that of the AC group ( 0.031).
Conclusion: Preservation of the peripheral capsule in vitrectomy combined with lens removal is a better option. This method has significant advantages in reducing intraoperative and postoperative complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8462261 | PMC |
http://dx.doi.org/10.12998/wjcc.v9.i26.7729 | DOI Listing |
Am J Ophthalmol Case Rep
March 2025
University of Florida, Department of Ophthalmology, USA.
Purpose: Human amniotic membrane (hAM) grafts have been used to close persistent macular holes in recent years. The results from these surgeries are promising with improved closure rate and vision. However, there is lack of data for what happens to these membranes and how long the tissue should remain inside the patient's eyes.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Smt. Kanuri Santhamma Centre for Vitreo Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India
A septuagenarian man presented with a visual acuity of hand motions and a large refractory macular hole (MH). We performed an autologous retinal transplant (ART) and covered the graft with fibrin glue without any endotamponade. The autograft was found to have dislocated from the MH when the patient was reviewed 1 week later.
View Article and Find Full Text PDFBackground: To report clinical outcomes from a single-center cohort undergoing PAUL® Glaucoma Implant (PGI) surgery for secondary glaucoma after vitreoretinal surgery (VR).
Methods: Retrospective review of patients undergoing PGI surgery at the University Eye Hospital Bonn, Germany, from 04/2021 to 05/2023.
Results: 33 eyes of 33 patients were included.
ACS Appl Mater Interfaces
January 2025
State Key Laboratory of Polymer Materials Engineering, College of Polymer Science and Engineering, Sichuan University, Chengdu, Sichuan 610065, P.R. China.
Silicone rubber (SR) holds significant potential for everyday wearable devices due to its inherent sweat resistance and flexibility. However, its broader applicability is constrained by poor oil resistance and a suboptimal slip performance. In this study, we developed an SR with durable oil resistance and enhanced slip properties by forming a covalently bonded barrier layer on its surface through a one-step in situ fluorination reaction using F/N.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian, Shenzhen 518000, China.
The effectiveness of ultraviolet-C light-emitting diodes (UVC LEDs) is currently limited by the lack of suitable encapsulation materials, restricting their use in sterilization, communication, and in vivo cancer tumor inhibition. This study evaluates various silicone oils for UVC LED encapsulation. A material aging experiment was conducted on CF1040 (octamethylcyclotetrasiloxane), HF2020 (methyl hydro polysiloxanes), and MF2020-1000 (polydimethylsiloxane) under UVC radiation for 1000 h.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!