Is the Ne operation of the helium ion microscope suitable for electron backscatter diffraction sample preparation?

Beilstein J Nanotechnol

Central Analytical Research Facility, Institute for Future Environments, Queensland University of Technology, 2 George St, Brisbane 4000, QLD, Australia.

Published: August 2021

Electron backscatter diffraction (EBSD) is a powerful characterization technique which allows the study of microstructure, grain size, and orientation as well as strain of a crystallographic sample. In addition, the technique can be used for phase analysis. A mirror-flat sample surface is required for this analysis technique and different polishing approaches have been used over the years. A commonly used approach is the focused ion beam (FIB) polishing. Unfortunately, artefacts that can be easily induced by Ga FIB polishing approaches are seldom published. This work aims to provide a better understanding of the underlying causes for artefact formation and to assess if the helium ion microscope is better suited to achieve the required mirror-flat sample surface when operating the ion source with Ne instead of He. Copper was chosen as a test material and polished using Ga and Ne ions with different ion energies as well as incident angles. The results show that crystal structure alterations and, in some instances, phase transformation of Cu to CuGa occurred when polishing with Ga ions. Polishing with high-energy Ne ions at a glancing angle maintains the crystal structure and significantly improves indexing in EBSD measurements. By milling down to a depth equaling the depth of the interaction volume, a steady-state condition of ion impurity concentration and number of induced defects is reached. The EBSD measurements and Monte Carlo simulations indicate that when this steady-state condition is reached more quickly, which can be achieved using high-energy Ne ions at a glancing incidence, then the overall damage to the specimen is reduced.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450971PMC
http://dx.doi.org/10.3762/bjnano.12.73DOI Listing

Publication Analysis

Top Keywords

helium ion
8
ion microscope
8
electron backscatter
8
backscatter diffraction
8
mirror-flat sample
8
sample surface
8
polishing approaches
8
fib polishing
8
crystal structure
8
high-energy ions
8

Similar Publications

Ion Spectroscopy in the Context of the Diffuse Interstellar Bands: A Case Study with the Phenylacetylene Cation.

ACS Earth Space Chem

December 2024

School of Chemistry, The University of Edinburgh, Joseph Black Building, David Brewster Road, King's Buildings, Edinburgh EH9 3FJ, Scotland, U.K.

Identification of the molecular carriers of diffuse interstellar bands (DIBs) requires gas phase electronic spectra of suitable candidate structures. Recording the spectra of these in the laboratory is challenging because they include large, carbon-rich molecules, many of which are likely to be ionic. The electronic spectra of ions are often obtained using action spectroscopy methods, which can induce small perturbations to the absorption characteristics and hinder comparison with astronomical observations.

View Article and Find Full Text PDF

Laser excitation of the 1-2 transition in singly-ionized helium.

Commun Phys

December 2024

LaserLaB, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, the Netherlands.

Laser spectroscopy of atomic hydrogen and hydrogen-like atoms is a powerful tool for tests of fundamental physics. The 1-2 transition of hydrogen in particular is a cornerstone for stringent Quantum Electrodynamics (QED) tests and for an accurate determination of the Rydberg constant. We report laser excitation of the 1-2 transition in singly-ionized helium (He), a hydrogen-like ion with much higher sensitivity to QED than hydrogen itself.

View Article and Find Full Text PDF

Ultrathin polymer membranes on porous substrates exhibit excellent gas and ion permeability and have important applications in many fields, such as membrane separation and batteries. However, there is still a lack of facile and general methods for the direct preparation of ultrathin polymer membranes on porous substrates, especially from polymer solutions. Within this work, a new strategy to fabricate centimeter-size ultrathin polymer membranes (thickness down to 16 nm) is presented directly on porous supports by using the liquid-liquid interfacial spin-coating technique.

View Article and Find Full Text PDF

In this work, a set of analytical techniques, including scanning electron microscopy (SEM), Raman scattering spectroscopy, X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray microanalysis (EDX) and cyclic voltammetry (CV), were used to study the impact of high-energy He ion irradiation on the structural and electrochemical characteristics of sulfur-containing multi-walled carbon nanotubes (S-MWCNTs) placed on a titanium substrate. The results indicate that the ion beam treatment of the S-MWCNT system led to an increase in the level of imperfections on the surface structures of the nanotubes due to the formation of point defects on their outer walls and the appearance of oxygen-containing functional groups, including SO groups, near these defects. At the same time, a significant increase in the sulfur concentration (by 6.

View Article and Find Full Text PDF

Accurate in situ carbon isotopic measurements of magnesium-rich carbonates using LA-MC-ICP-MS require effective correction for isobaric interference, particularly from doubly charged Mg ions that can induce δC deviations of several permil. This study focuses on optimizing gas parameters and developing robust correction strategies to improve the accuracy of δC measurements. Experimental results demonstrate that the introduction of nitrogen gas at a flow rate of 4-6 mL/min effectively doubles signal sensitivity while optimizing low helium (0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!