Background: The World Health Organization recommends research to evaluate the effects of a single third trimester Doppler ultrasound examination on preventable deaths in unselected-risk pregnancies, particularly in low- and middle-income countries (LMICs) where the evidence base is scarce. While evaluating such technologies, researchers often ignore women and health care provider perspectives. This study explored the views and experiences of women and healthcare providers regarding the use of advanced ultrasound technology to optimize the health of mothers and their babies in a rural community in mid-western Uganda.

Methods: We enrolled 53 mothers and 10 healthcare providers, and captured data on their perceptions, barriers, and facilitators to the use of Doppler ultrasound technology using focus group discussions, semi-structured interviews and observations. Using qualitative content analysis, we inductively coded the transcripts in ATLAS.ti 8.0, detecting emerging themes.

Results: Women were afraid that ultrasound would harm them or their fetuses and many of them had never seen an ultrasound scan. The majority of the women found their partners supportive to attend antenatal care and use ultrasound services. Healthcare providers in Kagadi Hospital were unfamiliar with Doppler technology and using it to guide clinical decisions. Other barriers to the implementation of Doppler ultrasound included shortage of trained local staff, insufficient equipment, long distance to and from the hospital, and frequent power cuts.

Conclusions: We found limited exposure to Doppler ultrasound technology among women and healthcare providers in mid-western Uganda. Engaging male partners may potentially influence the likelihood of accepting and using it to improve the health of women and their fetuses while wide spread myths and misconceptions about it may be changed by community engagement. Healthcare workers experienced difficulties in offering follow-up care to mothers detected with complications and Doppler ultrasound required a high level of training. While introducing advanced ultrasound machines to weak health systems, it is important to adequately train healthcare providers to avoid inappropriate interventions based on misinterpretation of the findings, consider where it is likely to be most beneficial, and embed it with realistic clinical practice guidelines.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8499453PMC
http://dx.doi.org/10.1186/s12978-021-01233-5DOI Listing

Publication Analysis

Top Keywords

doppler ultrasound
24
healthcare providers
24
women healthcare
12
ultrasound technology
12
ultrasound
11
advanced ultrasound
8
women
7
healthcare
7
providers
6
doppler
6

Similar Publications

In the context of neurodegenerative diseases, finger tapping is a gold-standard test used by clinicians to evaluate the severity of the condition. The finger tapping test involves repetitive tapping between the index finger and thumb. Subjects affected by neurodegenerative diseases, such as Parkinson's disease, often exhibit symptoms like bradykinesia, rigidity, and tremor.

View Article and Find Full Text PDF

Umbilical Artery Thrombosis Masquerading as Single Umbilical Artery in a Stillbirth.

Diagnostics (Basel)

January 2025

Department of Pathology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.

Umbilical artery thrombosis (UAT) masquerading as a single umbilical artery (SUA) is a rare but critical diagnostic challenge in prenatal care. We described a case of a 22-year-old primigravida with an uneventful obstetric history who presented with reduced fetal movements at 22 weeks of gestation. Ultrasound showed no gross fetal structural anomalies while umbilical artery Doppler flow imaging revealed an isolated SUA.

View Article and Find Full Text PDF

Effect of abnormal placental cord insertion on hemodynamic change of umbilical cord in a tertiary center: a prospective cohort study.

Postgrad Med J

January 2025

Department of Obstetrics and Gynecology, Chung Shan Hospital, No. 11, Ln. 112, Sec. 4, Ren'ai Rd., Da'an Dist., Taipei City 10689, Taiwan.

Background: Our study aims to evaluate the umbilical vein (UV) hemodynamic change in the prenatal cohort of pregnancies diagnosed with abnormal placental cord insertion (aPCI).

Methods: From January 2022 to December 2022, the fetal umbilical cord insertion site was sonographically examined in singleton fetuses, and umbilical cord blood flow was calculated. The umbilical artery and UV Doppler flow indexes were assessed in cases of normal and abnormal cord insertion.

View Article and Find Full Text PDF

Background: The sacroiliac joints (SIJ) are specialized articulations in the pelvis that allow load transfer between the upper and lower body. Traumatic pelvic disruption often requires surgical fixation of at least one of these joints. Subsequent SIJ pain is associated with asymmetries in joint laxity or stiffness.

View Article and Find Full Text PDF

Background: Gastrointestinal ultrasound (GIUS) is recommended for monitoring Crohn's disease (CD). GIUS scores are used to quantify CD activity. Among them, IBUS-SAS (International Bowel Ultrasound Segmental Activity Score), BUSS (Bowel Ultrasound Score), Simple-US (Simple Ultrasound Score), and SUS-CD (Simple Ultrasound Score for Crohn's Disease) are most commonly used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!