A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait. | LitMetric

The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait.

Gait Posture

KU Leuven, Department of Rehabilitation Sciences, Leuven, Belgium.

Published: October 2021

Background: Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown.

Research Question: What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants?

Methods: 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortable walking speed. An ultrasound probe was secured on the leg and tracked by 3D motion analysis. Images were collected during two walking trials with the probe on the MG muscle-belly to estimate FAS lengths and muscle thickness, and during two trials with the probe on the MTJ to estimate muscle-belly and tendon lengths. A second session was performed after 5 ± 4 days where a different operator placed the ultrasound probe. The standard deviation (SD) of absolute and relative lengths changes during the gait cycle over different trials were calculated per participant. SD values averaged over participants represented intra- and inter-session errors.

Results: For all assessed variables, the intra-session errors were <2.2 mm, except for the FAS lengths (3.1 mm). The inter-session errors were larger than the intra-session, with the highest values found for the absolute muscle-tendon unit lengths (5.6 mm). Relative length errors were smaller than absolute length errors.

Significance: Intra-session errors, which may reflect natural variability and data processing errors, seem more critical when extracting absolute FAS than muscle-tendon lengths. Standardized probe positioning on the MTJ between sessions may improve the inter-session reliability. Expressing the lengths relative to their lengths as the beginning of the gait cycle reduces the inter-session errors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2021.09.198DOI Listing

Publication Analysis

Top Keywords

medial gastrocnemius
8
muscle-tendon unit
8
unit lengths
8
lengths gait
8
motion analysis
8
muscle thickness
8
gait cycle
8
intra- inter-session
8
tendon lengths
8
ultrasound probe
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!