Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A sensitive and direct spectrofluorimetric method was developed for simultaneous quantitation of two co-administered drugs, namely, alfuzosin hydrochloride (AFH) and vardenafil hydrochloride (VRH). Both drugs exhibited native fluorescence properties that could be exploited to assay them in biological fluids with high sensitivity. Spectrofluorimetric analysis of AFH and VRH is based on excitation of both drugs at 265 nm where emission spectra were recorded separately for AFH and VRH at 380 and 485 nm, respectively. Micellar trends in analytical chemistry were adopted to minimize both environmental and occupational hazards, using distilled water and sodium dodecyl sulphate (serves as a micellar medium that enhanced the sensitivity of AFH and VRH) for analysis of both drugs in their raw materials, tablets, and human biological fluids (plasma and urine). Linearity ranges were 1.0-16.0 and 10.0-700.0 ng mL for AFH and VRH, respectively. The proposed method was successfully assessed for analysis of AFH and VRH in spiked human plasma and urine samples over the following concentrations: 1.0-12.0 ng mL and 4.0-400.0 ng mL for both drugs, simultaneously with mean recoveries of 101.08 % and 102.06 % in plasma and 96.75 % and 92.8 % in urine. Statistical analysis of the practical results has proved quite good agreement and revealed there were no significant differences in the accuracy and precision with those obtained by the comparison methods. The proposed method was applied successfully to Prostetrol® and Powerecta® commercial tablets without interference with tablet additives.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2021.120420 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!