A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantifying optical anisotropy in soft tissue membranes using Mueller matrix imaging. | LitMetric

Significance: A non-destructive technique for accurately characterizing the spatial distribution of optical properties of soft tissue membranes may give improved outcomes in many tissue engineering applications.

Aim: This study aimed to develop a non-destructive macroscopic imaging technique that is sensitive to optical anisotropy, typical of fibrous components in soft tissue membranes, and can address some of the difficulties caused by the complex turbid nature of these tissues.

Approach: A near-infrared Mueller matrix imaging polarimeter employing logarithm decomposition was developed and used to conduct transmission measurements of all the polarization properties across the full thickness of bovine pericardium tissue.

Results: The full Mueller matrix was measured across a 70  mm  ×  70  mm sample of calf bovine pericardium and revealed significant retardance (linear and circular) and depolarization in this tissue. Regions with a uniform axis of optical anisotropy were identified. Mueller matrix imaging demonstrated that the exhibited circular retardance was sufficient to lead to possible misinterpretation of apparent fiber orientation when using conventional polarization imaging techniques for such tissues.

Conclusions: Mueller matrix imaging can identify regional distributions of optical anisotropy in calf bovine pericardium. This new capability is a promising development in non-destructive imaging for tissue selection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8493487PMC
http://dx.doi.org/10.1117/1.JBO.26.10.106001DOI Listing

Publication Analysis

Top Keywords

mueller matrix
20
optical anisotropy
16
matrix imaging
16
soft tissue
12
tissue membranes
12
bovine pericardium
12
calf bovine
8
imaging
7
tissue
6
mueller
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!