Full-field swept-source optical coherence tomography (FF-SS-OCT) is an emerging technology with potential applications in ophthalmic imaging, microscopy, metrology, and other domains. Here we demonstrate a novel method of multiplexing FF-SS-OCT signals using carrier modulation (CM). The principle of CM could be used to inspect various properties of the scattered light, e.g. its spectrum, polarization, Doppler shift, or distribution in the pupil. The last of these will be explored in this work, where CM was used to acquire images passing through two different optical pupils. The two pupils contained semicircular optical windows with perpendicular orientations, with each window permitting measurement of scattering anisotropy in one dimension by inducing an optical delay between the images formed by the two halves of the pupil. Together, the two forms of multiplexing permit measurement of differential scattering anisotropy in the x and y dimensions simultaneously. To demonstrate the feasibility of this technique our carrier multiplexed directional FF-OCT (CM-D-FF-OCT) system was used to acquire images of a microlens array, human hair, onion skin and in vivo human retina. The results of these studies are presented and briefly discussed in the context of future development and application of this technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8687100PMC
http://dx.doi.org/10.1364/OE.435761DOI Listing

Publication Analysis

Top Keywords

acquire images
8
scattering anisotropy
8
simultaneous directional
4
directional full-field
4
full-field oct
4
oct path-length
4
path-length carrier
4
carrier multiplexing
4
multiplexing full-field
4
full-field swept-source
4

Similar Publications

Language is a sophisticated cognitive skill that relies on the coordinated activity of cerebral cortex. Acquiring a second language creates intricate modifications in brain connectivity. Although considerable studies have evaluated the impact of second language acquisition on brain networks in adulthood, the results regarding the ultimate form of adaptive plasticity remain inconsistent within the adult population.

View Article and Find Full Text PDF

Background: The spinal column is a frequent site for metastases, affecting over 30% of solid tumor patients. Identifying the primary tumor is essential for guiding clinical decisions but often requires resource-intensive diagnostics.

Purpose: To develop and validate artificial intelligence (AI) models using noncontrast MRI to identify primary sites of spinal metastases, aiming to enhance diagnostic efficiency.

View Article and Find Full Text PDF

Significance: Maximal safe resection of brain tumors can be performed by neurosurgeons through the use of accurate and practical guidance tools that provide real-time information during surgery. Current established adjuvant intraoperative technologies include neuronavigation guidance, intraoperative imaging (MRI and ultrasound), and 5-ALA for fluorescence-guided surgery.

Aim: We have developed intraoperative Raman spectroscopy as a real-time decision support system for neurosurgical guidance in brain tumors.

View Article and Find Full Text PDF

Aim: To compare three-dimensional (3D) facial morphology of various unilateral cleft subphenotypes at 9-years of age to normative data using a general face template and automatic landmarking. The secondary objective is to compare facial morphology of 9-year-old children with unilateral fusion to differentiation defects.

Methods: 3D facial stereophotogrammetric images of 9-year-old unilateral cleft patients were imported into 3DMedX® for processing.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!