Modelling the influence of age on the perception of brightness of visual stimuli is an important topic for indoor and outdoor lighting. As people get older, the transmittance of the ocular media becomes lower, especially in the blue wavelength region. This paper reports on an experimental study aiming to evaluate how the brightness perception of red and blue stimuli is affected by the age of the observer. A matching experiment has been set up in which both young (25 years old on average) and older (70 years old on average) adult observers had to match the brightness of a blue stimulus with the brightness of a red stimulus, both surrounded by a dark background (unrelated stimuli). A significant difference in brightness perception between the two groups of observers was found. In particular, older people report a decrease in brightness perception for the blue stimuli compared to younger people. The results show that the brightness correlate of the colour appearance model CAM18sl (applied with zero luminance background) adequately predicts the matching results of young observers, but failed to predict the results obtained by the older observers. As CAM18sl is built on cone fundamentals which include the transmittance of the ocular media and consider the age of the observer as an input parameter, the authors developed the idea to substitute the cone fundamentals for a young observer by the cone fundamentals for a 70 years old observer. This updated CAM18sl performed very well for the older observer as well, on condition that the transmittance of the ocular media is isolated and kept out of the normalization of the cone fundamentals.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.431382 | DOI Listing |
Micromachines (Basel)
January 2025
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
Objectives: To evaluate cases of persistent apical periodontitis (PAP) and what are the imaging and clinical aspects that could be considered in the PAP diagnosis and in their treatment decision-making process.
Methodology: 423 patients with apical periodontitis at the time of non-surgical root canal treatment (NSRCT) were followed-up for at least 1 year. Periapical radiographic images were used to compare and determine periapical status at each time using the PAI scoring system.
Natl J Maxillofac Surg
November 2024
Department of Oral Medicine and Maxillofacial Radiology, Dr. G. D. Pol Foundations YMT Dental College and Hospital, Navi Mumbai, Maharashtra, India.
Introduction: The tympanic cavity contains three tiny bones, the malleus, incus, and stapes, which have a fundamental role in the transmission of sound. Recent research emphasizes the use of CBCT for the anatomic study of the temporal bone. The information about middle ear anatomy on CBCT scans is meager; hence, this retrospective study was conducted to identify and determine the various morphometrical parameters of the malleus using CBCT which can be helpful during reconstructive procedures for the otologic surgeon.
View Article and Find Full Text PDFJ Vis
January 2025
Neural Information Processing Group, University of Tübingen, Tübingen, Germany.
Human performance in psychophysical detection and discrimination tasks is limited by inner noise. It is unclear to what extent this inner noise arises from early noise (e.g.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Department of Physics, Chung-Ang University, Seoul, 06974, Republic of Korea.
The fundamental characteristics of collective interactions in topological band structures can be revealed by the exploration of charge screening in topological materials. In particular, distinct anisotropic screening behaviors are predicted to occur in Dirac nodal line semimetals (DNLSMs) due to their peculiar anisotropic low-energy dispersion. Despite the recent extensive theoretical research, experimental observations of exotic charge screening in DNLSMs remain elusive, which is partly attributed to the coexisting trivial bands near the Fermi energy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!