A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Absolute calibration of a single-photon avalanche detector using a bright triggered single-photon source based on an InGaAs quantum dot. | LitMetric

We apply an InGaAs quantum dot based single-photon source for the absolute detection efficiency calibration of a silicon single-photon avalanche diode operating in Geiger mode. The single-photon source delivers up to (2.55 ± 0.02) × 10 photons per second inside a multimode fiber at the wavelength of 929.8 nm for above-band pulsed excitation with a repetition rate of 80 MHz. The purity of the single-photon emission, expressed by the value of the 2 order correlation function g(τ = 0), is between 0.14 and 0.24 depending on the excitation power applied to the quantum dot. The single-photon flux is sufficient to be measured with an analog low-noise reference detector, which is traceable to the national standard for optical radiant flux. The measured detection efficiency using the single-photon source remains constant within the measurement uncertainty for different photon fluxes. The corresponding weighted mean thus amounts to 0.3263 with a standard uncertainty of 0.0022.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.430680DOI Listing

Publication Analysis

Top Keywords

single-photon source
16
quantum dot
12
single-photon
8
single-photon avalanche
8
ingaas quantum
8
detection efficiency
8
absolute calibration
4
calibration single-photon
4
avalanche detector
4
detector bright
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!