During the early months of the current COVID-19 pandemic, social distancing measures effectively slowed disease transmission in many countries in Europe and Asia, but the same benefits have not been observed in some developing countries such as Brazil. In part, this is due to a failure to organise systematic testing campaigns at nationwide or even regional levels. To gain effective control of the pandemic, decision-makers in developing countries, particularly those with large populations, must overcome difficulties posed by an unequal distribution of wealth combined with low daily testing capacities. The economic infrastructure of these countries, often concentrated in a few cities, forces workers to travel from commuter cities and rural areas, which induces strong nonlinear effects on disease transmission. In the present study, we develop a smart testing strategy to identify geographic regions where COVID-19 testing could most effectively be deployed to limit further disease transmission. By smart testing we mean the testing protocol that is automatically designed by our optimization platform for a given time period, knowing the available number of tests, the current availability of ICU beds and the initial epidemiological situation. The strategy uses readily available anonymised mobility and demographic data integrated with intensive care unit (ICU) occupancy data and city-specific social distancing measures. Taking into account the heterogeneity of ICU bed occupancy in differing regions and the stages of disease evolution, we use a data-driven study of the Brazilian state of Sao Paulo as an example to show that smart testing strategies can rapidly limit transmission while reducing the need for social distancing measures, even when testing capacity is limited.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8494319PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0257235PLOS

Publication Analysis

Top Keywords

smart testing
16
social distancing
12
distancing measures
12
disease transmission
12
developing countries
8
testing
8
smart
4
testing critical
4
critical care
4
care bed
4

Similar Publications

High Performance of Cs2AgBiBr6 Perovskite-based Photodetectors by Adding DEAC.

Chemistry

December 2024

East China University of Science and Technology, School of Materials Science and Engineering, meilong Road, 200237, shanghai, CHINA.

Perovskite-based photodetectors (PDs) are broadly utilized in optical communication, non-destructive testing, and smart wearable devices due to their ability to convert light into electrical signals. However, toxicity and instability hold back their mass production and commercialization. The lead-free Cs2AgBiBr6 double perovskite film, promised to be an alternative, is fabricated by electrophoretic deposition (EPD), which compromises film quality.

View Article and Find Full Text PDF

Continued efforts to discover new antibacterial molecules are critical to achieve a robust pre-clinical pipeline for new antibiotics. Screening of compound or natural product extract libraries remains a widespread approach and can benefit from the development of whole cell assays that are robust, simple and versatile, and allow for high throughput testing of antibacterial activity. In this study, we created and validated two bioluminescent reporter strains for high-throughput screening, one in Pseudomonas aeruginosa, and another in a hyperporinated and efflux-deficient Escherichia coli.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is one of the most common cardiac arrhythmias of clinical relevance and a major cause of cardiovascular morbidity and mortality. Following a diagnosis of AF, patients are directed towards therapy with anticoagulant drugs to reduce the thromboembolic risk and antiarrhythmics to control their cardiac rhythm, with periodic follow-up checks. Despite the great ease of handling these drugs, we soon realized the need for follow-up models that would allow the appropriateness and safety of these pharmacological treatments to be monitored over time.

View Article and Find Full Text PDF

Accuracy and Reliability of Grip Strength Measurements: A Comparative Device Analysis.

J Funct Morphol Kinesiol

December 2024

University Center for Prevention and Sports Medicine, Balgrist University Hospital, University of Zurich, CH-8008 Zurich, Switzerland.

Grip strength is widely used as a surrogate parameter for functional status. The current gold standard, the JAMAR Hydraulic Dynamometer (JAMAR Hydraulic), presents challenges for individuals with painful finger joints or low grip strength. Therefore, the objective of this observational study was to assess comparability across the JAMAR Smart, the Martin Vigorimeter and the gold standard.

View Article and Find Full Text PDF

Organ-on-a-chip (OOC) devices mimic human organs, which can be used for many different applications, including drug development, environmental toxicology, disease models, and physiological assessment. Image data acquisition and analysis from these chips are crucial for advancing research in the field. In this study, we propose a label-free morphology imaging platform compatible with the small airway-on-a-chip system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!