A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Targeting repeatability of a less obtrusive surgical navigation procedure for total shoulder arthroplasty. | LitMetric

Purpose: Surgical navigation systems have demonstrated improvements in alignment accuracy in a number of arthroplasty procedures, but they have not yet been widely adopted for use in total shoulder arthroplasty (TSA). We believe this is due in part to the obtrusiveness of conventional optical tracking systems, as well as the need for additional intraoperative steps such as calibration and registration. The purpose of this study is to evaluate the feasibility of adapting a less-intrusive dental navigation system for use in TSA.

Methods: We developed a proof-of-concept system based on validated laser-engraved surgical tools recently introduced for use in dental surgery that are calibrated once when manufactured and not recalibrated at time of use. The design also features a notably smaller bone-mounted tracker that can be tracked from a wide range of viewing angles. To assess our system's performance, we modified the dental surgical software to support guidance of a TSA procedure. We then conducted a user study in which three participants with varying surgical experience used the system to drill 30 holes in a glenoid model. Using a coordinate measuring machine, we determined the resulting drilled trajectory and compared this to the pre-planned trajectory. Since we used a model glenoid rather than anatomical specimens, we report on targeting precision rather than overall procedure precision or accuracy.

Results: We found targeting precision < 1 mm (standard deviation) for locating the entry hole and <  ~ 1° (SD) for both version and inclination. The latter value was markedly lower than the end-to-end angular precision achieved by previously reported TSA navigation systems (approximately 3°-5° SD).

Conclusion: We conclude that variability during the targeting phase represents a small fraction of the overall variability exhibited by existing systems, so a less obtrusive navigation system for TSA based on laser-engraved tooling is likely feasible, which could improve the uptake rates of surgical navigation for TSA, thereby potentially leading to improved overall surgical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-021-02503-0DOI Listing

Publication Analysis

Top Keywords

surgical navigation
8
total shoulder
8
shoulder arthroplasty
8
targeting precision
8
surgical
5
targeting repeatability
4
repeatability obtrusive
4
obtrusive surgical
4
navigation procedure
4
procedure total
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!