A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A three-dimensional biomodel of type A aortic dissection for endovascular interventions. | LitMetric

A three-dimensional biomodel of type A aortic dissection for endovascular interventions.

J Artif Organs

Department of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.

Published: June 2022

Thoracic endovascular aortic repair is widely used for type B aortic dissection. However, there is no favorable stent-graft for type A aortic dissection. A significant limitation for device development is the lack of an experimental model for type A aortic dissection. We developed a novel three-dimensional biomodel of type A aortic dissection for endovascular interventions. Based on Digital Imaging and Communication in Medicine data from the computed tomography image of a patient with a type A aortic dissection, a three-dimensional biomodel with a true lumen, a false lumen, and an entry tear located at the ascending aorta was created using laser stereolithography and subsequent vacuum casting. The biomodel was connected to a pulsatile mock circuit. We conducted four tests: an endurance test for clinical hemodynamics, wire insertion into the biomodel, rapid pacing, and simulation of stent-graft placement. The biomodel successfully simulated clinical hemodynamics; the target blood pressure and cardiac output were achieved. The guidewire crossed both true and false lumens via the entry tear. The pressure and flow dropped upon rapid pacing and recovered after it was stopped. This simulation biomodel detected decreased false luminal flow by stent-graft placement and detected residual leak. The three-dimensional biomodel of type A aortic dissection with a pulsatile mock circuit achieved target clinical hemodynamics, demonstrated feasibility for future use during the simulated endovascular procedure, and evaluated changes in the hemodynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-021-01294-0DOI Listing

Publication Analysis

Top Keywords

type aortic
28
aortic dissection
28
three-dimensional biomodel
16
biomodel type
12
clinical hemodynamics
12
aortic
8
dissection endovascular
8
endovascular interventions
8
entry tear
8
pulsatile mock
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!