Background: Advanced pancreatic ductal adenocarcinoma (PDAC) is characterized by progressive weight loss and nutritional deterioration. This wasting has been linked to poor survival outcomes, alterations in host defenses, decreased functional ability, and diminished health-related quality of life (HRQOL) in pancreatic cancer patients. There are currently no standardized approaches to the management of pancreatic cancer cachexia. This study explores the feasibility and efficacy of enteral tube feeding of a peptide-based formula to improve weight stability and patient-reported outcomes (PROs) in advanced PDAC patients with cachexia.

Methods: This was a single-institution, single-arm prospective trial conducted between April 2015 and March 2019. Eligible patients were adults (>18 years) diagnosed with advanced or locally advanced PDAC and cachexia, defined as greater than 5% unexplained weight loss within 6 months from screening. The study intervention included three 28 day cycles of a semi-elemental peptide-based formula, administered through a jejunal or gastrojejunal feeding tube. The primary outcome was weight stability at 3 months (Cycle 3), defined as weight change less than 0.1 kg/baseline BMI unit from baseline. Secondary outcomes included changes in lean body mass, appendicular lean mass, bone mineral density, fat mass, and percent body fat, as measured with a DEXA scan, HRQOL (EORTC QLQC30) and NIH PROMIS PROs assessed at each cycle. Daily activity (steps, distance, active minutes, heart rate, and sleep) were remotely monitored using a wearable activity monitor (Fitbit) over the 3 month study period.

Results: Thirty-six patients were screened for eligibility, 31 patients consented onto study and underwent jejunal tube placement, and 16 patients completed treatment: mean age 67 years (SD 9.3), 43.8% male. Among evaluable patients (n = 16), weight stability was achieved in 10 patients (62.5%), thus completing the trial early. Increases in lean body mass (1273.1, SD: 4078, P = 0.01) and appendicular lean mass (0.45, SD: 0.6, P = 0.02) were observed. Statistically significant improvements at Cycle 3 from baseline were also observed for QLQC30 role function [mean difference (MD): 20.1, P = 0.03], appetite (MD: 27.4, P = 0.02), and global health scores (MD: 13.3, P = 0.05) as well as for NIH PROMIS t-scores for depression (MD: -10.4, P = 0.006) and pain interference (MD: -7.5, P = 0.05). Objectively monitored (Fitbit) activity levels increased, although statistical significance was not reached.

Conclusions: Our findings suggest that enteral nutrition support may improve weight stability, lean body mass, appendicular lean mass and PROs in PDAC patients with cachexia who completed treatment, representing a subsample of the study population. The feasibility and role of enteral feeding in routine care remain unclear, and larger and randomized controlled trials are warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8718084PMC
http://dx.doi.org/10.1002/jcsm.12799DOI Listing

Publication Analysis

Top Keywords

weight stability
20
lean body
16
body mass
16
pancreatic cancer
12
appendicular lean
12
lean mass
12
patients
9
feasibility efficacy
8
efficacy enteral
8
enteral tube
8

Similar Publications

Bio-inspired carbon-based artificial muscle with precise and continuous morphing capabilities.

Natl Sci Rev

January 2025

CAS Key Laboratory of Organic Solids, Beijing National Laboratory for Molecular Sciences (BNLMS), CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

In the face of advancements in microrobotics, intelligent control and precision medicine, artificial muscle actuation systems must meet demands for precise control, high stability, environmental adaptability and high integration miniaturization. Carbon materials, being lightweight, strong and highly conductive and flexible, show great potential for artificial muscles. Inspired by the butterfly's proboscis, we have developed a carbon-based artificial muscle, hydrogen-substituted graphdiyne muscle (HsGDY-M), fabricated efficiently using an emerging hydrogen-substituted graphdiyne (HsGDY) film with an asymmetrical surface structure.

View Article and Find Full Text PDF

Tropomyosin is an actin-binding protein that plays roles ranging from regulating muscle contraction to controlling cytokinesis and cell migration. The simple nematode provides a useful model for studying the core functions of tropomyosin in an animal, having a relatively simple anatomy, and a single tropomyosin gene, , that produces seven isoforms. Three higher molecular weight isoforms (LEV-11A, D, O) regulate contraction of body wall and other muscles, but comparatively less is known of the functions of four lower molecular weight isoforms (LEV-11C, E, T, U).

View Article and Find Full Text PDF

Effect of Hyaluronan Molecular Weight on the Stability and Biofunctionality of Microfibers Assembled by Interfacial Polyelectrolyte Complexation.

ACS Appl Mater Interfaces

January 2025

3B's Research Group, I3Bs─Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-694 Barco, Guimarães, Portugal.

Nervous system disorders are characterized by a progressive loss of function and structure of neurons that ultimately leads to a decline in cognitive and motor functions. In this study, we used interfacial polyelectrolyte complexation (IPC) to produce fibers for neural tissue regeneration. IPC is a processing method that allows spinning of sensitive biopolymers.

View Article and Find Full Text PDF

Background: In order to increase the stability of tibial component in total knee arthroplasty (TKA), intramedullary stem extensions (SE) have been developed. The aim of this systematic review and meta-analysis is to address the critical knowledge gap on post-operative outcomes and complications rate comparison between tibial component with SE compared to the tibial component standard configuration (SC) in primary cemented TKA.

Methods: We conducted a comprehensive search of online databases, including Pubmed, Embase, ISI Web of science, Cochrane Library, and Scopus, using the following MeSH terms, (total knee arthroplasty) OR (TKA) OR (total knee replacement) AND (Tibial stem) OR (stem extension) OR (long stem).

View Article and Find Full Text PDF

Background: Long-term endurance training is associated with structural, functional, and biochemical markers of cardiac dysfunction in highly trained athletes. Many studies have focused on structural changes in the right ventricle (RV) and few have examined functional adaptation of the right ventricle. This meta-analysis aims to compare the changes in right ventricular systolic function between endurance athletes and controls before and after exercise using speckle tracking echocardiography (STE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!