A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effectiveness of EMG-driven neuromusculoskeletal model calibration is task dependent. | LitMetric

Calibration of neuromusculoskeletal models using functional tasks is performed to calculate subject-specific musculotendon parameters, as well as coefficients describing the shape of muscle excitation and activation functions. The objective of the present study was to employ a neuromusculoskeletal model of the shoulder driven entirely from muscle electromyography (EMG) to quantify the influence of different model calibration strategies on muscle and joint force predictions. Three healthy adults performed dynamic shoulder abduction and flexion, followed by calibration tasks that included reaching, head touching as well as active and passive abduction, flexion and axial rotation, and submaximal isometric abduction, flexion and axial rotation contractions. EMG data were simultaneously measured from 16 shoulder muscles using surface and intramuscular electrodes, and joint motion evaluated using video motion analysis. Muscle and joint forces were calculated using subject-specific EMG-driven neuromusculoskeletal models that were uncalibrated and calibrated using (i) all calibration tasks (ii) sagittal plane calibration tasks, and (iii) scapular plane calibration tasks. Joint forces were compared to published instrumented implant data. Calibrating models across all tasks resulted in glenohumeral joint force magnitudes that were more similar to instrumented implant data than those derived from any other model calibration strategy. Muscles that generated greater torque were more sensitive to calibration than those that contributed less. This study demonstrates that extensive model calibration over a broad range of contrasting tasks produces the most accurate and physiologically relevant musculotendon and EMG-to-activation parameters. This study will assist in development and deployment of subject-specific neuromusculoskeletal models.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2021.110698DOI Listing

Publication Analysis

Top Keywords

model calibration
16
calibration tasks
16
neuromusculoskeletal models
12
abduction flexion
12
calibration
10
emg-driven neuromusculoskeletal
8
neuromusculoskeletal model
8
muscle joint
8
joint force
8
flexion axial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!