Purpose: To compare the biomechanical properties of the knotted versus knotless transosseous-equivalent (TOE) techniques for rotator cuff repair (RCR).

Methods: A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines using PubMed, Embase, and the Cochrane Library to identify studies that compared the biomechanical properties of knotted and knotless TOE RCR techniques. The search phrase used was as follows: (Double Row) AND (rotator cuff) AND (repair) AND (biomechanical). Evaluated properties included ultimate load to failure, cyclic displacement, stiffness, footprint characteristics, and failure mode.

Results: Eight studies met the inclusion criteria, including a total of 67 specimens in each group. Of 6 studies reporting on ultimate load to failure, 4 found tendons repaired with the knotted TOE technique to experience significantly higher ultimate load to failure compared with knotless TOE repairs (knotted range, 323.5-549.0 N; knotless range, 166.0-416.8 N; P < .05). Of 6 studies reporting on failure stiffness, 2 found knotted TOE repairs to have significantly higher failure stiffness compared with knotless TOE repairs (knotted range, 30.0-241.8 N/mm; knotless range, 28.0-182.5 N/mm; P < .05), whereas 1 study found significantly higher failure stiffness in knotless TOE repairs compared with knotted TOE repairs (P = .039). Cyclic gap formation favored the knotted TOE group in 2 of 3 studies (knotted range, 0.6-5.2 mm; knotless range, 0.4-9.1 mm; P < .05). The most common mode of failure in both groups was suture tendon tear.

Conclusions: On the basis of the included cadaveric studies, rotator cuff tendons repaired via the knotted TOE technique display superior time-zero biomechanical properties, including greater ultimate load to failure, compared with rotator cuffs repaired via the knotless TOE technique. Suture tearing through the tendon remains a common failure method for both techniques.

Clinical Relevance: The results of this systematic review provide helpful insight into the biomechanical differences between 2 popular techniques for RCR. Although these results should be carefully considered by surgeons who are using either of these techniques in the operating room, they should not be mistaken for direct clinical applicability because cadaveric studies may not directly correlate to clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2021.09.017DOI Listing

Publication Analysis

Top Keywords

knotless toe
20
knotted toe
20
toe repairs
20
rotator cuff
16
biomechanical properties
16
ultimate load
16
load failure
16
cuff repair
12
compared knotless
12
systematic review
12

Similar Publications

Background: The purpose of this study is to report outcomes of an arthroscopic knotless double-row (DR) rotator cuff repair (RCR) technique at 2- and 5- years postoperatively, and to compare clinical outcomes in patients undergoing knotless DR RCR with incorporated lateral row biceps tenodesis (LRT) vs. those without LRT.

Methods: All primary RCR surgeries were performed by a single surgeon at a single institution using a knotless transosseous equivalent (TOE) technique.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how different techniques at the rotator cuff tendon-bone interface, specifically at the medial bearing row, affect local mechanical forces, area, and pressure.
  • It compares knotless transosseous equivalent repairs with different anchor configurations in a synthetic model, assessing various forces and pressures.
  • The findings suggest that medial row mechanisms and lateral row tension significantly influence these mechanical parameters, providing valuable insights for surgical technique selection.
View Article and Find Full Text PDF

Purpose: To compare failure rates and outcomes after transosseous equivalent (TOE) double row (DR) knotted suture bridge versus knotless suture tape bridge repair techniques for rotator cuff tears.

Methods: A consecutive series of 272 shoulders in 256 patients who underwent arthroscopic, double row, TOE repair for full-thickness tears of the supraspinatus tendon were reviewed. Eighty-four shoulders were repaired using knotted suture bridge (KSB) technique, and 188 shoulders were repaired using all knotless suture tape bridge (KTB) technique.

View Article and Find Full Text PDF

Purpose: To compare the biomechanical properties of the knotted versus knotless transosseous-equivalent (TOE) techniques for rotator cuff repair (RCR).

Methods: A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines using PubMed, Embase, and the Cochrane Library to identify studies that compared the biomechanical properties of knotted and knotless TOE RCR techniques. The search phrase used was as follows: (Double Row) AND (rotator cuff) AND (repair) AND (biomechanical).

View Article and Find Full Text PDF

Background: Modern rotator cuff repair techniques demonstrate favorable early and midterm outcomes, but long-term results have yet to be reported.

Purpose: To determine 10-year outcomes and survivorship after arthroscopic double-row transosseous-equivalent (TOE) rotator cuff repair.

Study Design: Case series; Level of evidence 4.