Unexpected Anesthetic Circuit Leak Attributed to Improper Use of a Tube Holder: A Case Report.

Anesth Prog

Division of Dental Anesthesiology, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan.

Published: October 2021

Leaks involving the anesthesia circuit can cause significant complications including hypoxia and hypoventilation. We present a case of a circuit leak caused by damage to the corrugated tubing attributed to improper use of the tube holder. A 58-year-old male was scheduled for resection of a palatal tumor under an intubated general anesthetic. After successful nasotracheal intubation, the anesthesiologist inserted the corrugated tubing of the anesthetic circuit into the tube holder. A leaking sound was heard and a tear in the corrugated tubing was promptly discovered. The corrugated tubing of the anesthetic circuit presumably tore because it was inserted into the groove of the tube holder at an inappropriate angle with excessive force. Anesthesiologists should be aware of potential leaks if the anesthesia circuit is damaged, which may be caused by improper use of tube holders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8500317PMC
http://dx.doi.org/10.2344/anpr-68-02-02DOI Listing

Publication Analysis

Top Keywords

tube holder
16
corrugated tubing
16
anesthetic circuit
12
improper tube
12
circuit leak
8
attributed improper
8
anesthesia circuit
8
tubing anesthetic
8
circuit
6
tube
5

Similar Publications

Nuclear explosion in a densely populated area is the worst that can happen to any country in the world due to enormous loss of life, property and severe economic damage. Nuclear explosions immediately cause radiological damage and destruction of infrastructure. This hydro-magnetic shock propagation due to blast gives rise to simultaneous signals around the world.

View Article and Find Full Text PDF

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy.

Ultramicroscopy

December 2024

Condensed Matter Physics and Material Science Department, Brookhaven National Laboratory, Upton, NY 11973, USA. Electronic address:

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. This article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.

View Article and Find Full Text PDF

A simple method has been developed for semi-quantitative analysis of the colorimetric output of loop-mediated isothermal amplification (LAMP) using a 3D-printed tube holder with a smartphone and notebook for the detection of Raillietina, which is the cause of Raillietiniasis affecting free-range chicken farming. In this method, a light is directed from a notebook screen to the LAMP products in the tube holder and the color absorption of the LAMP products is measured by using the appropriate smartphone application. It was found that the malachite green dye-coupled LAMP (MaG-LAMP) assay showed the highest sensitivity and specificity for detecting Raillietina without any cross-reaction with other related parasites and hosts.

View Article and Find Full Text PDF

Atomic structures of a bacteriocin targeting Gram-positive bacteria.

Nat Commun

August 2024

Department of Microbiology, Immunology and Molecular Genetics, University of California, Los Angeles (UCLA), Los Angeles, CA, USA.

Due to envelope differences between Gram-positive and Gram-negative bacteria, engineering precision bactericidal contractile nanomachines requires atomic-level understanding of their structures; however, only those killing Gram-negative bacteria are currently known. Here, we report the atomic structures of an engineered diffocin, a contractile syringe-like molecular machine that kills the Gram-positive bacterium Clostridioides difficile. Captured in one pre-contraction and two post-contraction states, each structure fashions six proteins in the bacteria-targeting baseplate, two proteins in the energy-storing trunk, and a collar linking the sheath with the membrane-penetrating tube.

View Article and Find Full Text PDF

Introduction: Patients in intensive care may have a tracheostomy and be dependent on a respiratory ventilator while yet conscious and able to mobilise. Early rehabilitation is known to be key to patient recovery. However, for these patients, therapy staff members are required to manage the ventilator tubing in addition to other patient-connected equipment whilst focussing on patient mobility and progress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!