Purpose: The study aimed to compare clinical and radiographic parameters of peri-implant site of laser-microgrooved implants with either laser-microgrooved or regular machined prosthetic abutment post 3 years of early loading.

Method: Twenty edentulous sites of systemically and periodontally healthy individuals were allocated into two groups in this prospective, two-armed, randomized double-blinded clinical trial in 1:1 ratio, wherein each site received laser-microgrooved implants with either laser-microgrooved or machined prosthetic abutments. Outcome measures included full-mouth plaque (FMPS%) and bleeding score (FMBS%), site-specific plaque (SPS%) and bleeding score (SBS%), peri-implant sulcus depth (PISD mm), and mean crestal bone loss (MCBL mm) evaluated at baseline (6 weeks), 1 and 3 years post-early loading. Mean and standard deviation of all parameters were estimated, between groups and at different time points using independent and paired t-test, respectively, Normality was checked using Kolmogorov-Smirnov test and Shapiro-Wilk test, P value ≤ 0.05 was considered as statistically significant.

Results: Three-year follow-up of test group showed statistically significant reduction in SPS, SBS, PISD (P value ≤ 0.001). The MCBL reduced from 1.93 mm to 0.61 mm (P value ≤ 0.001); in other words, a bone gain of 0.15 mm was obtained in the test group.

Conclusion: Within the limitations of the present study, laser-microgrooved implants loaded with laser-microgrooved prosthetic abutments showed superior results clinically and radiographically when compared to loading with machined abutments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8487924PMC
http://dx.doi.org/10.1186/s40729-021-00382-3DOI Listing

Publication Analysis

Top Keywords

laser-microgrooved implants
12
crestal bone
8
clinical trial
8
implants laser-microgrooved
8
machined prosthetic
8
prosthetic abutments
8
bleeding score
8
laser-microgrooved
6
influence laser-microgrooved
4
laser-microgrooved implant
4

Similar Publications

The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed.

View Article and Find Full Text PDF

Background: Many techniques have been proposed to address post-extraction ridge resorption, which often represents a concern, especially in the esthetic region.

Purpose: The purpose of the present, prospective, multicenter, single cohort study was to investigate, up to 1 year of function, the effectiveness of a protocol for alveolar ridge preservation involving implants with laser-microgrooved surface immediately placed in fresh extraction sockets.

Materials And Methods: Twenty eight patients candidate to tooth extraction in the esthetic zone (site 15-25 and 35-45) were treated by immediate placement of a single laser-microgrooved implants with the adjunct of a highly porous anorganic porcine bone mineral matrix and a collagen wound dressing.

View Article and Find Full Text PDF

Long-term dental implant success is dependent on biocompatibility and osseointegration between the bone and the implant. Surface modifications such as laser-induced microgrooving which increase contact area can enhance osseointegration by establishing and directing a stable attachment between the implant surface and peri-implant bone. The objective of this study was to evaluate pre-osteoblast proliferation, morphology, and differentiation on titanium alloy (Ti64) surfaces-Laser-Lok (LL), resorbable blast textured (RBT), and machined (M)-compared to tissue culture plastic (TCP) control.

View Article and Find Full Text PDF

Aim: To compare the clinical and radiographic conditions and the expression of pro-inflammatory cytokines in peri-implant crevicular fluid (PICF) at two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of loading.

Materials And Methods: In total, 20 single TP/BL implants and 20 contralateral OP/TL implants, both with a laser-microgrooved collar surface, in 20 systemically and periodontally healthy subjects (12 males and 8 females, between the age of 36 and 64 [mean age of 49.7 ± 12.

View Article and Find Full Text PDF

Purpose: Previous studies assessing fibroblast interactions with implants have mainly relied on measurements such as cell migration, gene expression, and cell adhesion. For these studies, testing cellular behavior at the implant surface was done by imaging the cell-implant interface using standard microscopy techniques in 2D tissue culture dishes. The true behavior of cells relative to the implant can best be assessed in a more physiologic 3D microenvironment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!