Kinetic Analysis of a Protein-protein Complex to Determine its Dissociation Constant (K) and the Effective Concentration (EC) of an Interplaying Effector Molecule Using Bio-layer Interferometry.

Bio Protoc

Organismic Interactions Department, Interfaculty Institute for Microbiology and Infection Medicine, Cluster of Excellence 'Controlling Microbes to Fight Infections', Tübingen University, Auf der Morgenstelle 28, 72076 Tübingen, Germany.

Published: September 2021

Biolayer interferometry (BLI) is an emerging analytical tool that allows the study of protein complexes in real time to determine protein complex kinetic parameters. This article describes a protocol to determine the K of a protein complex using a 6×His tagged fusion protein as bait immobilized on the NTA sensor chip of the FortéBio Octet K2 System (Sartorius). We also describe how to determine the half maximal effective concentration (EC, also known as IC for inhibiting effectors) of a metabolite. The complete protocol allows the determination of protein complex K and small molecular effector EC within 8 h, measured in triplicates. Graphic abstract: (Middle, top) Exemplary result of the BLI measurement using Octet (Raw Data). Wavelength shift (Δλ) against time. (A) Baseline 1. Baseline measurement. When the sensor is equilibrated in the kinetics buffer. The light is reflected with no difference. (B) Load. The his-tagged proteins (ligand) are loaded onto the sensor surface. The light is reflected with a shift of the wavelength. (C) Baseline 2. The loaded sensor is equilibrated in the kinetics buffer. No further wavelength shift appears. (D) Association. The loaded sensor is dipped into the analyte solution. The analyte binds to the immobilized ligand along with an increased wavelength shift. (E) Dissociation. Afterward, the sensor is dipped again into the kinetics buffer without the analyte. Some analyte molecules dissociate. The wavelength shift decreases. (Subfigures A-E) The left side shows the position of the sensor during the measurement seen in the representative BLI measurement, marked with the figure label. The right side shows the light path in the sensor. Black waves represent the light emitted to the sensor surface. The red waves show the light reflected from the sensor surface back to the detector.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8443453PMC
http://dx.doi.org/10.21769/BioProtoc.4152DOI Listing

Publication Analysis

Top Keywords

wavelength shift
16
protein complex
12
kinetics buffer
12
light reflected
12
loaded sensor
12
sensor surface
12
sensor
10
effective concentration
8
determine protein
8
bli measurement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!