Introduction: The use of mobile devices for electrocardiogram (ECG) recording and the ability to use this technology to immediately review dynamic waveforms is growing tremendously. While over-the-counter ECG devices may display rhythm disorders and ST-segment changes at rest, changes during physical exercise have thus far not been evaluated. We compared a mobile device (smartphone/tablet)-enabled vectorial 4-electrode ECG system (SPE) with the current standard 12‑lead (STE) ECG both at rest and during exercise.
Methods And Results: A total of 428 patients underwent simultaneous ECG testing with both technologies during rest and maximal exercise. The vectorial ECG was displayed as 12‑lead ECG, and diagnostic accuracy and ECG quality (independently judged by blinded cardiologists) were compared with the current standard. Signal quality was good with both ECG technologies. At rest, there was excellent agreement between SPE and STE regarding rhythm (98%), AV-conduction (97%), wave duration (90%), and electrical axis (88-97%). During exercise the presence or absence of ST-deviation (>0.1 mm) corresponded in 90% of cases with no statistically significant difference. The positive predictive value was 48.5% and the negative predictive value was 94%. For ST-deviations >0.2 mm the percentage match was 97% during exercise. For rhythm disorders and for intraventricular conduction (left- and right-bundle branch block detection) it was >90%.
Conclusion: A smart-device-enabled vectorial ECGs system using the CardioSecur system can be used in daily practice to reliably interpret an ECG at rest and during physical exercise, although it is less accurate with respect to the detection of ST-deviation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2021.09.013 | DOI Listing |
Intern Emerg Med
January 2025
Faculty of Medicine, Department of Emergency Medicine, Akdeniz University, Antalya, Turkey.
Patients presenting with suspected acute coronary syndrome (ACS) in the emergency department (ED) require rapid and accurate electrocardiographic (ECG) evaluation. This study aims to assess conventional ECG markers for diagnosing non-ST-elevation ACS (NSTE-ACS) in patients with chest discomfort and right bundle branch block (RBBB). A nested case-control design was employed to compare patients with RBBB admitted to the ED for suspected cardiac ischemia, focusing on those who developed NSTE-ACS versus those who did not.
View Article and Find Full Text PDFMitochondrion
January 2025
The Department of Blood Circulation of Bogomoletz Institute of Physiology of the National Academy of Sciences of Ukraine, Kyiv, Ukraine. Address: 4, Bogomoletz Str., Kyiv 01024, Ukraine.
Pyridoxal-5-phosphate (PLP) enhances the synthesis of endogenous hydrogen sulfide, a potent regulator of cell metabolism. We used 24-month-old rats to investigate the PLP mitoprotective function in the aging heart. We demonstrated improvement of mitochondrial bioenergetic functions, inhibition of mPTP opening after PLP administration.
View Article and Find Full Text PDFJ Electrocardiol
December 2024
VPG Medical, Inc., Rochester, NY, USA.
Passive cardiac monitoring has become synonymous with wearable technologies, necessitating patients to incorporate new devices into their daily routines. While this requirement may not be a burden for many, it is a constraint for individuals with chronic diseases who already have their daily routine. In this study, we introduce an innovative technology that harnesses the front-facing camera of smartphones to capture pulsatile signals discreetly when users engage in other activities on their device.
View Article and Find Full Text PDFEur J Med Res
January 2025
Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, China.
Background: Astragalus injection has been utilized in traditional Chinese medicine to treat a variety of diseases. The purpose of this systematic review was to evaluate the effectiveness of Astragalus injection in the treatment of viral myocarditis.
Methods: English databases such as PubMed, Cochrane Library, and EMBASE, and Chinese databases of Sino Med, China National Knowledge Infrastructure (CNKI), the VIP Information Resource Integration Service Platform, and Wanfang Data Information Site, were searched from their inception until May 1, 2024.
NPJ Digit Med
January 2025
Instituto de Investigación Sanitaria Fundación Jiménez Díaz, Madrid, Spain.
Unnecessary preoperative testing poses a risk to patient safety, causes surgical delays, and increases healthcare costs. We describe the effects of implementing a fully EHR-integrated closed-loop clinical decision support system (CDSS) for placing automatic preprocedural test orders at two teaching hospitals in Madrid, Spain. Interrupted time series analysis was performed to evaluate changes in rates of preoperative testing after CDSS implementation, which took place from September 2019 to December 2019.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!