A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the Intrahospital and Long-Term Survival of Heart Transplant Patients With a Short-Term Mechanical Assistance Device. | LitMetric

Analysis of the Intrahospital and Long-Term Survival of Heart Transplant Patients With a Short-Term Mechanical Assistance Device.

Transplant Proc

Heart Failure and Transplant Unit, La Fe University and Polytechnic Hospital, Valencia, Spain; Department of Cardiology, La Fe University and Polytechnic Hospital, Valencia, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, Spain; University of Valencia, Valencia, Spain.

Published: November 2021

Background: The purpose of this study was to compare early and late survival among patients who have undergone heart transplantation (HTx) with a short-term mechanical assist device.

Methods: This was an ambispective, single-center, consecutive study of patients undergoing urgent HTx for 5 years. Pediatric transplants, retransplants, and combined transplants were excluded. Forty-five patients were included. Four groups were analyzed: those with venoarterial extracorporeal membrane oxygenation (ECMO) implanted <10 days before HTx; those with ECMO implanted for >10 days; patients classified as INTERMACS 2 to 3 with Levitronix Centrimag implanted; and those classified as INTERMACS 2 with Levitronix Centrimag implanted. Survival and the influence of orotracheal intubation (OI) at the time of transplantation were compared.

Results: There were differences in in-hospital mortality (P = .03) and total mortality (P = .06). The groups with the highest risk for mortality were those who carried ECMO for >10 days before transplantation or those classified as INTERMACS 2 with Levitronix Centrimag implanted. In these groups, the need for posttransplant circulatory support was also greater (P = .04) as was the length of stay in critical care (P = .02). The need for OI during the days of care and until transplantation had a negative effect on survival in all groups (P < .1).

Conclusions: There are different risk subgroups among patients who are transplanted with a circulatory/ventricular assist device. The lowest mortality occurs when the days of ECMO implantation are <10 and when the implanted device is a Levitronix Centrimag in INTERMACS 2 to 3 profile, particularly when the patient reaches the HTx without requiring OI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transproceed.2021.06.030DOI Listing

Publication Analysis

Top Keywords

classified intermacs
12
intermacs levitronix
12
levitronix centrimag
12
centrimag implanted
12
short-term mechanical
8
patients
6
analysis intrahospital
4
intrahospital long-term
4
survival
4
long-term survival
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!