A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and optimization of scanning magnets for HUST-PTF. | LitMetric

Design and optimization of scanning magnets for HUST-PTF.

Rev Sci Instrum

State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, Hubei, People's Republic of China.

Published: September 2021

We report scanning magnets manufactured at the Huazhong University of Science and Technology Proton Therapy Facility for use in pencil-beam nozzles in a fixed beamline. Such nozzles allow us to control the trajectory of proton beams to form the requisite radiation field for tumor therapy. Two AC-excited scanning magnets operate at a maximum frequency of 100 and 50 Hz, respectively, generating significant eddy currents that raise the temperature. We use transient electromagnetic analysis and thermal analysis to study the eddy current effect and control the temperature. In this paper, the maximum temperature rise of the scanning magnets is taken as the criterion to find the appropriate depth, shape, and distribution of slits. After the slits are optimized, the temperature rise of the scanning magnet is significantly reduced. Finally, the results of DC performance tests satisfy the requirements of the magnetic field.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0053382DOI Listing

Publication Analysis

Top Keywords

scanning magnets
16
temperature rise
8
rise scanning
8
scanning
5
design and optimization
4
optimization scanning
4
magnets
4
magnets hust-ptf
4
hust-ptf report
4
report scanning
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!