A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

UTERINE ARTERY EMBOLISATION: CONTINUOUS QUALITY IMPROVEMENT REDUCES RADIATION DOSE WHILE MAINTAINING IMAGE QUALITY. | LitMetric

UTERINE ARTERY EMBOLISATION: CONTINUOUS QUALITY IMPROVEMENT REDUCES RADIATION DOSE WHILE MAINTAINING IMAGE QUALITY.

Radiat Prot Dosimetry

Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia.

Published: November 2021

The purpose of this study was to introduce a continuous quality improvement (CQI) program for radiation dose optimisation during uterine artery embolisation (UAE) and assess its impact on dose reduction and image quality. The CQI program investigated the effects of optimising radiation dose parameters on the kerma-area product (KAP) and image quality when comparing a 'CQI intervention' group (n = 50) and 'Control' group (n = 50). Visual grading characteristics (VGC) analysis was used to assess image quality, using the 'Control' group as a reference. A significant reduction in KAP by 17% (P = 0.041, d = 0.2) and reference air kerma (Ka, r) by 20% (P = 0.027, d = 0.2) was shown between the two groups. The VGC analysis resulted in an area under the VGC curve (AUCVGC) of 0.54, indicating no significant difference in image quality between the two groups (P = 0.670). The implementation of the CQI program and optimisation of radiation dose parameters improved the UAE radiation dose practices at our centre. The dose reduction demonstrated no detrimental effects on image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncab145DOI Listing

Publication Analysis

Top Keywords

image quality
24
radiation dose
20
cqi program
12
uterine artery
8
artery embolisation
8
quality
8
continuous quality
8
quality improvement
8
dose reduction
8
dose parameters
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!