Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques.

OTO Open

Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany.

Published: September 2021

Objective: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT).

Study Design: Retrospective data analyses of 42 cochleae.

Setting: Tertiary care medical center.

Methods: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method.

Results: CDL values were significantly shorter in MRI by MPR ( = 1.38 mm, < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR ( = 1.67 mm) and ECA ( = 1.19 mm, both < .001). In contrast, angular length was significantly higher in MRI ( = 26.79°, < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL).

Conclusion: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698PMC
http://dx.doi.org/10.1177/2473974X211045312DOI Listing

Publication Analysis

Top Keywords

2-turn length
12
cochlear duct
8
duct length
8
length measurements
8
computed tomography
8
magnetic resonance
8
resonance imaging
8
presented study
8
horos software
8
cdl 2-turn
8

Similar Publications

Article Synopsis
  • The study explores the concept of the "velocity barrier" (VB) in alpine skiing, which represents the maximum speed a skier can achieve while controlling their path through the gates.
  • Researchers tested this by having fourteen skiers navigate a Giant Slalom course under different speed conditions and measuring their performance metrics such as entrance velocity and force production.
  • The findings support the existence of the VB, showing that skiers were unable to increase their force output beyond this threshold, leading to higher energy dissipation and longer path lengths when attempting to go faster.
View Article and Find Full Text PDF

Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques.

OTO Open

September 2021

Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany.

Objective: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

DNA tensegrity triangles self-assemble into rhombohedral three-dimensional crystals via sticky ended cohesion. Crystals containing two-nucleotide (nt) sticky ends (GA:TC) have been reported previously, and those crystals diffracted to 4.9 Å at beamline NSLS-I-X25.

View Article and Find Full Text PDF

Conclusion: The cochlear length (CL) and cochlear height (CH) measured through MPR will provide for more accurate quantitative diagnosis of inner ear malformation, and are subsequently convenient for calculating cochlear duct length (CDL) before cochear implant.

Objectives: Qualitative and quantitative diagnosis of inner ear malformation in deaf patients through multiplanar reconstruction (MPR) was performed to provide a reference for cochlear implants.

Methods: One hundred and two cases without sensorineural deafness and 560 patients with sensorineural deafness had MPR of temporal bone computed tomography performed to obtain the standardized cochlear-view and oblique coronal-view images.

View Article and Find Full Text PDF

An optically inactive poly(4-carboxyphenyl isocyanide) (poly-1-H) changed its structure into the prevailing, one-handed helical structure upon complexation with optically active amines in dimethylsulfoxide (DMSO) and water, and the complexes show a characteristic induced circular dichroism in the polymer backbone region. Moreover, the macromolecular helicity induced in water and aqueous organic solutions containing more than 50 vol % water could be "memorized" even after complete removal of the chiral amines (h-poly-1b-H), while that induced in DMSO and DMSO-water mixtures containing less than 30 vol % water could not maintain the optical activity after removal of the chiral amines (poly-1a-H). We now report fully detailed studies of the helix induction mechanism with chiral amines and the memory of the macromolecular helicity in water and a DMSO-water mixture by various spectroscopic measurements, theoretical calculations, and persistence length measurements together with X-ray diffraction (XRD) measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!