Objective: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT).
Study Design: Retrospective data analyses of 42 cochleae.
Setting: Tertiary care medical center.
Methods: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method.
Results: CDL values were significantly shorter in MRI by MPR ( = 1.38 mm, < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR ( = 1.67 mm) and ECA ( = 1.19 mm, both < .001). In contrast, angular length was significantly higher in MRI ( = 26.79°, < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL).
Conclusion: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477698 | PMC |
http://dx.doi.org/10.1177/2473974X211045312 | DOI Listing |
Scand J Med Sci Sports
January 2024
Inter-University Laboratory of Human Movement Sciences, Université Savoie Mont Blanc, Chambéry, France.
OTO Open
September 2021
Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany.
Objective: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI).
View Article and Find Full Text PDFACS Nano
July 2019
Department of Chemistry , Purdue University, West Lafayette , Indiana 47907 , United States.
DNA tensegrity triangles self-assemble into rhombohedral three-dimensional crystals via sticky ended cohesion. Crystals containing two-nucleotide (nt) sticky ends (GA:TC) have been reported previously, and those crystals diffracted to 4.9 Å at beamline NSLS-I-X25.
View Article and Find Full Text PDFActa Otolaryngol
February 2017
a Department of Otorhinolaryngology Head and Neck Surgery , The First Affiliated Hospital of GuangXi Medical University, NanNing , GuangXi , PR China.
Conclusion: The cochlear length (CL) and cochlear height (CH) measured through MPR will provide for more accurate quantitative diagnosis of inner ear malformation, and are subsequently convenient for calculating cochlear duct length (CDL) before cochear implant.
Objectives: Qualitative and quantitative diagnosis of inner ear malformation in deaf patients through multiplanar reconstruction (MPR) was performed to provide a reference for cochlear implants.
Methods: One hundred and two cases without sensorineural deafness and 560 patients with sensorineural deafness had MPR of temporal bone computed tomography performed to obtain the standardized cochlear-view and oblique coronal-view images.
J Am Chem Soc
August 2009
Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya 464-8603, Japan.
An optically inactive poly(4-carboxyphenyl isocyanide) (poly-1-H) changed its structure into the prevailing, one-handed helical structure upon complexation with optically active amines in dimethylsulfoxide (DMSO) and water, and the complexes show a characteristic induced circular dichroism in the polymer backbone region. Moreover, the macromolecular helicity induced in water and aqueous organic solutions containing more than 50 vol % water could be "memorized" even after complete removal of the chiral amines (h-poly-1b-H), while that induced in DMSO and DMSO-water mixtures containing less than 30 vol % water could not maintain the optical activity after removal of the chiral amines (poly-1a-H). We now report fully detailed studies of the helix induction mechanism with chiral amines and the memory of the macromolecular helicity in water and a DMSO-water mixture by various spectroscopic measurements, theoretical calculations, and persistence length measurements together with X-ray diffraction (XRD) measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!