Left ventricular assist devices (LVADs) have been increasingly used as a therapy for patients with end-stage heart failure. However, a growing number of clinical observations have shown that LVADs are associated with thromboembolic events, which are potentially related to the changes in intraventricular flow. Particularly, the flow fields around the inflow cannula (IC) of the LVAD. In this study, a fluid structure interaction (FSI) simulation was conducted to evaluate the hemodynamics of a patient specific left ventricle (LV) with varying LVAD IC orientations. The LV model was obtained from computed tomography scans and modeled to have contraction and relaxation during cardiac cycles following available experimental data of LV volume changes. The LV of the patient was assumed to have an end systolic volume of 223.7 mL and a stroke volume of 46.4 mL. Four different IC positions were considered: towards the (1) septum; (2) aortic valve (AV); (3) mitral valve (MV) and (4) inferior wall (IW). The potential thrombus growth around the IC was assumed to be caused by blood stagnation regions with low velocity (<5 mm/s) and low shear rate (<60/s) flow. Mean velocity magnitudes and low blood velocity regions around the IC were numerically obtained. To quantitatively compare the thrombosis risks of the four simulation cases, the time-averaged volumes of the low-velocity regions and the low shear rate regions were calculated. The intraventricular volumes of low velocity zones based on IC orientation are 1.42 mL toward the septum, 1.14 mL toward the AV, 0.93 mL toward the MV, and 1.24 mL toward the IW. The intraventricular volumes of low shear regions based on IC orientation are 11.54 mL toward the septum, 11.15 mL toward the AV, 9.24 mL toward the MV, and 10.7 mL toward the IW. IC orientation toward the MV results in lower volumetric regions of low flow and low shear within the ventricle, which consequently may lead to a reduced risk of thrombus formation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238172PMC
http://dx.doi.org/10.1080/10255842.2021.1984433DOI Listing

Publication Analysis

Top Keywords

inflow cannula
8
numerical study
4
study lvad
4
lvad inflow
4
cannula positioning
4
positioning thrombosis
4
thrombosis risk
4
risk left
4
left ventricular
4
ventricular assist
4

Similar Publications

End-stage heart failure due to left ventricular noncompaction (LVNC) poses unique challenges for ventricular assist device implantation, like inflow cannula obstruction due to trabeculations. We report a case of an 11-year-old boy with LVNC who underwent successful HeartWare implantation as a bridge to transplant for high pulmonary vascular resistance and had successful heart transplantation after 4 years of HeartWare support.

View Article and Find Full Text PDF

Transcatheter Aspiration of Tricuspid Vegetation.

JACC Case Rep

December 2024

Jesselson Integrated Heart Center, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel.

Objective: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.

Key Steps: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.

Potential Pitfalls: Avoid leaflet and annular injury and account for potential embolization.

View Article and Find Full Text PDF

"Caution with choroidals" - choose the right one at right time.

Indian J Ophthalmol

December 2024

Department of Oculoplasty, Disha Eye Hospitals Pvt Ltd, Kolkata, West Bengal, India.

Article Synopsis
  • Choroidal detachment (CD) during retinal detachment surgery can negatively affect surgical results and vision, necessitating specific management techniques.
  • Cannula-guided choroidal drainage is essential for mitigating pre-existing CDs, especially in complex cases with hemorrhagic detachment.
  • Intraoperative sudden CD can be caused by issues like hypotony or air entry from cannula slippage, which may lead to serious complications like Venous Air Embolism (VAE); prompt action to stop air infusion is critical to prevent life-threatening outcomes.
View Article and Find Full Text PDF

Objective: A less-invasive left atrial assist device (LAADx) is a novel and implantable, extracardiac blood pump concept, intended for the treatment of diastolic heart failure, represented by heart failure with preserved ejection fraction.

Methods: A mixed-flow pump was used as the working LAADx model. Its performance was evaluated at 3 speeds, using an in vitro pulsatile mock circulatory loop, with a pneumatic pump that can simulate diastolic heart failure conditions by adjusting the diastolic drive pressure.

View Article and Find Full Text PDF

The role of TandemHeart combined with ProtekDuo as right ventricular support device: A simulation approach.

Comput Methods Programs Biomed

December 2024

National Research Council, Institute of Clinical Physiology (IFC-CNR), 00185 Rome, Italy; Faculty of Medicine, Teaching University Geomedi, 0114 Tbilisi, Georgia. Electronic address:

Background And Objective: Right ventricular failure increases short-term mortality in the setting of acute myocardial infarction, cardiogenic shock, advanced left-sided heart failure and pulmonary arterial hypertension. Percutaneous and surgically implanted right ventricular assist devices (RVAD) have been investigated in different clinical settings. The use of the ProtekDuo™ is currently a promising approach due to its features such as groin-free approach leading to early mobilisation, easy percutaneous deployment, compatibility with different pumps and oxygenators, and adaptability to different configurations.

View Article and Find Full Text PDF