A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

How fast, how far: Diversification and adoption of novel methods in aquatic microplastic monitoring. | LitMetric

How fast, how far: Diversification and adoption of novel methods in aquatic microplastic monitoring.

Environ Pollut

School of Interdisciplinary Studies, University of Glasgow, Dumfries, Great Britain, United Kingdom. Electronic address:

Published: December 2021

Since 2004, there has been a marked diversification in the methods used to determine aquatic microplastic (MP) concentrations. Despite calls for a unified approach to MP sampling, the proliferation of new methods has accelerated in recent years. Both minor method adaptations and entirely novel approaches have been introduced to overcome barriers to reliable MP sampling, extraction and quantification, resulting in a variety of complimentary but also competing approaches. However, there is little clarity regarding the extent to which new methods are acknowledged and adopted, or of the apparent drivers of, as well as barriers to, said adoption. To explore these issues, the rate of method diversification was examined in a systematic review. The rate and degree of diversification were determined by scoring each method by its "degree of novelty": highly novel methods, secondary adaptations of existing methods and smaller, tertiary adaptations of existing methods. This analysis revealed that the rate of method diversification has been greatest since 2011. Our results indicate limited use of these novel methods and adaptations in the subsequent literature, with many researchers falling back on methods that are well established in the existing literature. Importantly, there is little consistency in the units used when reporting MP concentrations. However, these differences are seldom driven by method selection and are rather the result of discrepancies between researchers. Thus, in understanding the requirements of comparability and consistent reporting for monitoring purposes, we can apply a diverse approach to sampling whilst maintaining the applicability and usefulness of the resulting data.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envpol.2021.118174DOI Listing

Publication Analysis

Top Keywords

novel methods
12
methods
9
aquatic microplastic
8
approach sampling
8
rate method
8
method diversification
8
adaptations existing
8
existing methods
8
method
5
fast diversification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!