Background: Minimal invasive laparoscopic resection of liver tumors is less traumatic compared with open surgical resection and may be a better option for many patients. However, localization of intrahepatic tumors remains a challenge. Availability of hybrid operating rooms, equipped for high performance radiologic imaging, allows for new methods of surgical navigation.
Methods: Twelve patients planned for laparoscopic resection of liver tumors were included. Before resection started, tumors were marked with radiopaque fiducials. Four fiducials were positioned with ultrasound within 1 cm of the tumor. Tumor and fiducials were localized with contrast enhanced cone beam computed tomography. Fluoroscopy with an overlay of cone beam computed tomography markings was projected side-by-side on the same screen as the laparoscopic view to visualize tumor location. The fiducials were eventually removed. Laparoscopic ultrasound, the standard method of localizing a tumor, was also used. The benefits of the 2 visualization methods were estimated by the operator. Procedure times, radiation doses and resection margins were recorded.
Results: Fluoroscopy with radiopaque fiducials provided valuable information, complementing the laparoscopic ultrasound, particularly during the early phase of resection. In the later phase, mobilization of the tumor-containing liver segment caused significant displacement of the fluoroscopic overlay. The technique evolved during course of the study, with decreasing procedure times and radiation doses. Radical resection was achieved for all patients.
Conclusions: Radiopaque fiducials and fluoroscopy can complement laparoscopic ultrasound for guiding resection of liver tumors. Combining radiologic and optical imaging in a hybrid operating suit may facilitate development of augmented reality techniques for surgical navigation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8812418 | PMC |
http://dx.doi.org/10.1097/SLE.0000000000000991 | DOI Listing |
Int J Radiat Oncol Biol Phys
December 2024
Department of Radiation Oncology, Davidoff Cancer Center, Rabin Medical Center, Petah Tikvah, Israel.
Front Oncol
June 2024
Department of Radiation Oncology, Davidoff Cancer Center, Rabin Medical Center, Petah Tikvah, Israel.
Introduction: Precise patient positioning with image guidance (IGRT) is essential for safe prostate radiotherapy. We present the first report of utilizing a CT-visible hydrogel spacer, used to decrease rectal radiation dose, as a surrogate fiducial marker to aid in daily IGRT with cone-beam CT (CBCT) in stereotactic radiotherapy (SABR) for prostate cancer.
Materials And Methods: Prior to CT simulation, patients underwent placement of three intraprostatic gold fiducial markers and radiopaque hydrogel spacer per standard practice.
BMC Cancer
April 2024
Department of Radiation Oncology, Davidoff Cancer Center, Rabin Medical Center, 39 Ze'ev Jabotinsky St, Petah Tikvah, Israel.
Background: Dose-escalated radiotherapy is known to improve progression free survival in patients with localized prostate cancer, and recent advances have led to the standardization of ultrahypofractionated stereotactic ablative radiotherapy (SABR) delivered in just 5-fractions. Based on the known effectiveness of the accepted though invasive 2-fraction treatment method of high-dose-rate brachytherapy and given the ubiquity of prostate cancer, a further reduction in the number of treatments of external-beam SABR is possible. This study aims to evaluate the safety, efficacy, and non-inferiority of generalizable 2-fraction SABR compared to the current 5-fraction regimen.
View Article and Find Full Text PDFJ Neurosci Methods
July 2024
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA. Electronic address:
Background: High-precision neurosurgical targeting in nonhuman primates (NHPs) often requires presurgical anatomical mapping with noninvasive neuroimaging techniques (MRI, CT, PET), allowing for translation of individual anatomical coordinates to surgical stereotaxic apparatus. Given the varied tissue contrasts that these imaging techniques produce, precise alignment of imaging-based coordinates to surgical apparatus can be cumbersome. MRI-compatible stereotaxis with radiopaque fiducial markers offer a straight-forward and reliable solution, but existing commercial options do not fit in conformal head coils that maximize imaging quality.
View Article and Find Full Text PDFJ Stomatol Oral Maxillofac Surg
December 2024
Department of Prosthodontics, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, PR China. Electronic address:
When anatomical landmarks are missing or obstructed by metal artefacts, it is challenging to accurately merge cone beam computed tomography (CBCT) and intraoral scanning (IOS) information, and the accuracy of the implant surgical guides would be compromised. This article describes a novel technical note using oral wound dressings and flowable resin as additional new radiopaque fiducial landmarks to design surgical guides for full-arch immediate implant placement. This technical note provided an accurate, convenient, and cost-effective option for the clinician.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!