The management of infected nonunion associated with bone loss in long bones is both a time-consuming and challenging procedure for the orthopedic and trauma surgeon. In this paper, we present the case of a 75-year-old woman with infected nonunion of the distal femur associated with bone loss after plate osteosynthesis for a distal femur fracture. The patient was referred for nonunion of the distal femur after plate fixation (nonlocking "classic" plate) and was treated with a locking compression plate (LCP) and autologous cancellous bone transplant. During the follow-up, the patient was ambulatory without pain; however, the nonunion failed to heal, therefore, the induced membrane technique (Masquelet procedure) was performed in two stages, tissue samples were taken and revealed a bacterial infection (), and antibiotic treatment was started. Due to infection, fracture healing was slowed, but did commence. Unfortunately, the LC plate failed before union occurred, the nonunion was treated with a femoral nail and blocking (Poller) screws, and the bony defect was filled with Ca-P cement. The patient was operated one last time for cement dislocation when not only the dislocated cement was removed but also the femoral nail dynamized. After one year after treatment completion, the fracture healed, and leg length discrepancy was 1.5 cm shorter on the left side. The patient experienced significant pain relief and can walk with the help of crutches. Our paper demonstrates the application of different techniques in fracture surgery as they are required can result in fracture healing even in very adverse circumstances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464431PMC
http://dx.doi.org/10.1155/2021/3530297DOI Listing

Publication Analysis

Top Keywords

distal femur
16
infected nonunion
12
nonunion distal
12
bone loss
12
associated bone
8
fracture healing
8
femoral nail
8
nonunion
5
plate
5
fracture
5

Similar Publications

Distal femoral replacement (DFR) with megaprostheses is a salvage revision total knee arthroplasty (rTKA) procedure indicated in cases with massive bone defects in the distal femur. As long as these implants achieve fixation only in the diaphysis, the high aseptic loosening rate reported in some series is probably related to a lack of rotational stability. Two patients with extensive distal femoral bone defects with preservation of the metaphyseal-diaphyseal junction underwent rTKA.

View Article and Find Full Text PDF

Background: Aim of the present paper is to report the preliminary results of CAD-CAM (Computer-Aided Design - Computer-Aided Manufacturing) technology application to distal femur nonunion treatment with free fibula flap, custom made medial plating and maintenance of a stable lateral locking plate.

Methods: Two cases of distal femur nonunion that occurred after lateral locking plating were treated and prospectively followed-up. Surgical planning followed the same preoperative protocol adopted for mandibular CAD-CAM reconstruction.

View Article and Find Full Text PDF

The current study aimed to objectively evaluate the fit of a rectangular, tapered stem to the severely dysplastic hips on the basis of the proximal femoral anatomy and the dimensional properties of the stem. It was hypothesized that the stem size planned with accordance to the diaphyseal canal width alone can accommodate the distal femur successfully with no sizing mismatch. Forty-six patients (53 hips) suffering from secondary osteoarthritis due to hip dysplasia scheduled for total hip arthroplasty (THA) with a subtrochanteric transverse shortening osteotomy were included.

View Article and Find Full Text PDF

Background: Long-leg alignment and joint line obliquity have traditionally been assessed using two-dimensional (2D) radiography, but the accuracy of this measurement has remained unclear. This study aimed to evaluate the accuracy of 2D measurements of lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) using upright three-dimensional (3D) computed tomography (CT).

Methods: This study involved 66 knees from 38 patients (34 women, four men) with knee osteoarthritis (OA), categorized by Kellgren-Lawrence (KL) grade.

View Article and Find Full Text PDF

High mortality among elderly with surgical treated femoral fracture in comparison to other surgical treated lower extremity fractures. A population-based register study from the Danish National Patient Registry.

Injury

January 2025

Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Denmark; Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital - University Hospital of Southern Denmark, Denmark; Department of Clinical Research, University of Southern Denmark, Denmark.

Background: Proximal femoral fractures has been associated with high mortality risk, while little is known about more distal lower extremity fractures. The aim was to report 30- and 365-days mortality in surgically treated lower extremity fractures in individuals above 65 years.

Materials And Methods: We extracted data from the Danish National Patient Register on all surgically treated lower extremity fracture in the period 1998-2017.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!