Cardiac auscultation is one of the most popular diagnosis approaches to determine cardiovascular status based on listening to heart sounds with a stethoscope. However, heart sounds can be masked by visceral sounds such as organ movement and breathing, and a doctor's level of experience can more seriously affect the accuracy of auscultation results. To improve the accuracy of auscultation, and to allow nonmedical staff to conduct cardiac auscultation anywhere and anytime, a hybrid-type personal smart stethoscope with an automatic heart sound analysis function is presented in this paper. The device was designed with a folding finger-ring shape that can be worn on the finger and placed on the chest to measure photoplethysmogram (PPG) signals and acquire the heart sound simultaneously. The measured heart sounds are detected as phonocardiogram (PCG) signals, and the boundaries of the heart sound variation and the peaks of the PPG signal are detected in preprocessing by an advanced Shannon entropy envelope. According to the relationship between PCG and PPG signals, an automatic heart sound analysis algorithm based on calculating the time interval between the first and second heart sounds (S1, S2) and the peak of the PPG was developed and implemented via the manufactured prototype device. The prototype device underwent accuracy and usability testing with 20 young adults, and the experimental results showed that the proposed smart stethoscope could satisfactorily collect the heart sounds and PPG signals. In addition, within the developed algorithm, the device was as accurate in start-points of heart sound detection as professional physiological signal-acquisition systems. Furthermore, the experimental results demonstrated that the device was able to identify S1 and S2 heart sounds automatically with high accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8472017PMC
http://dx.doi.org/10.3390/s21186294DOI Listing

Publication Analysis

Top Keywords

heart sound
24
heart sounds
24
smart stethoscope
12
heart
12
automatic heart
12
ppg signals
12
stethoscope automatic
8
cardiac auscultation
8
accuracy auscultation
8
sound analysis
8

Similar Publications

Stress and psychological disorders are substantial public health concerns, necessitating innovative therapeutic strategies. This study investigated the psychophysiological benefits of nature-based soundscapes, drawing on the biophilia hypothesis. Using a randomized, acute cross-over design, 53 healthy participants experienced either a nature-based or a reference soundscape for 10 min, with a 2-min washout period.

View Article and Find Full Text PDF

Certain interoceptive hunger cues are caused by gut physiology. These interoceptive cues may have psychological consequences, namely an ability to enhance the desire to eat, which are independent of their physiological cause. Testing this idea is difficult because the physiological processes are normally linked to any consequence.

View Article and Find Full Text PDF

The cortex and cerebellum are densely connected through reciprocal input/output projections that form segregated circuits. These circuits are shown to differentially connect anterior lobules of the cerebellum to sensorimotor regions, and lobules Crus I and II to prefrontal regions. This differential connectivity pattern leads to the hypothesis that individual differences in structure should be related, especially for connected regions.

View Article and Find Full Text PDF

Background: Andersen-Tawil syndrome (ATS) is a rare autosomal dominant disorder caused by variants in the gene. It is associated with periodic paralysis, dysmorphic features and cardiac arrhythmias. The syndrome exhibits incomplete penetrance, leading to a broad spectrum of clinical manifestations, making diagnosis challenging.

View Article and Find Full Text PDF

Background: The known and established benefits of exercise in patients with heart failure (HF) are often hampered by low exercise adherence. Mobile health (mHealth) technology provides opportunities to overcome barriers to exercise adherence in this population.

Objective: This systematic review builds on prior research to (1) describe study characteristics of mHealth interventions for exercise adherence in HF including details of sample demographics, sample sizes, exercise programs, and theoretical frameworks; (2) summarize types of mHealth technology used to improve exercise adherence in patients with HF; (3) highlight how the term "adherence" was defined and how it was measured across mHealth studies and adherence achieved; and (4) highlight the effect of age, sex, race, New York Heart Association (NYHA) functional classification, and HF etiology (systolic vs diastolic) on exercise adherence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!