Inflammatory bowel disease (IBD) is a chronic condition affecting primarily the gastrointestinal tract and characterized by growing incidence worldwide. Complex diagnostic process of IBD as well as evaluation of disease activity and intestinal complications that are crucial for the therapeutic decisions, require repetitive, invasive, expensive, time-consuming and poorly tolerated tests. In contrast to endoscopy and computed tomography, ultrasound elastography (UE) is non-invasive, non-radiating and non-contrasting dependent tool which might be utilized in IBD patients for the assessment of the intestinal changes. Therefore, we performed the systematic review to evaluate the possible application of the ultrasound elastography for assessment of the intestinal changes in IBD. After the search of three databases: PubMed, World of Knowledge and Scopus, we identified 12 papers which were included in the final analysis. The majority of the studies were focused on the evaluation of the symptomatic ileal/ileocolonic strictures in Crohn's disease patients that required surgical resection. Only one study concerned ulcerative colitis. The authors evaluated different UE techniques: strain elastography (SE), acoustic radiation force impulse (ARFI) and shear wave elastography (SWE). Results were expressed with semi-quantitative color mapping and strain measurement. Histological scores of inflammation and fibrosis in Crohn's disease were used as a reference test in the majority of studies. Ultrasound elastography seems to be a promising novel imaging technique supporting evaluation of the intestinal strictures in Crohn's disease patients in respect to fibrosis detection as well as differentiation between fibrosis and inflammation. However, further research is needed to establish the position of ultrasound elastography in IBD management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8470999PMC
http://dx.doi.org/10.3390/jcm10184044DOI Listing

Publication Analysis

Top Keywords

ultrasound elastography
20
assessment intestinal
12
intestinal changes
12
crohn's disease
12
elastography assessment
8
inflammatory bowel
8
majority studies
8
strictures crohn's
8
disease patients
8
elastography
6

Similar Publications

Exploring the influence of perineal biometrics and stiffness measured by elastography during pregnancy on perineal tears : a pilot study.

J Gynecol Obstet Hum Reprod

January 2025

Nanomedicine Imaging and Therapeutics Laboratory, INSERM EA 4662, University of Franche-Comte, Besançon, France; CHU de Besançon, Service de Gynécologie-Obstétrique, Besançon, France.

Objectives: This study aimed to describe the biometrics and elasticity of the perineal body and the anal sphincter in the ninth month of pregnancy and explore their association with the risk of perineal tears during childbirth.

Methods: In this prospective observational study, pregnant women at 36-40 weeks of gestation were included. Using transperineal 2D-mode ultrasound and shear wave elastography (SWE), we measured the biometrics and stiffness of the perineal body (PB), external anal sphincter (EAS), internal anal sphincter (IAS), and anal mucosa (AM) at rest and during Valsalva maneuvers.

View Article and Find Full Text PDF

Rett syndrome (RTT) is a neurodevelopmental disorder caused by mutations in the gene, potentially disrupting lipid metabolism and leading to dyslipidemia (DLD) and steatotic liver disease (SLD). Although SLD has been described in RTT mouse models, it remains undocumented in humans. We herein describe a 24-year-old woman with RTT who was evaluated for abnormal liver enzymes.

View Article and Find Full Text PDF

Purpose: Obesity and type 2 diabetes (T2DM) are major risk factors for hepatic steatosis. Diet or bariatric surgery can reduce liver volume, fat content, and inflammation. However, little is known about their effects on liver function, as evaluated here using the LiMAx test.

View Article and Find Full Text PDF

Background: The study focuses on the use of multi-parametric ultrasound [gray scale, color Doppler and shear wave elastography (SWE)] to differentiate stable renal allografts from acute graft dysfunction and to assess time-dependent changes in parenchymal stiffness, thereby assessing its use as an efficient monitoring tool for ongoing graft dysfunction. To date, biopsy is the gold standard for evaluation of acute graft dysfunction. However, because it is invasive, it carries certain risks and cannot be used for follow-up monitoring.

View Article and Find Full Text PDF

With the availability of free antiretroviral therapy (ART) across India, HIV in adults has become a chronic disease with prolonged survival. The emergence of various non-communicable diseases in these prolonged survivors is a cause of concern. Metabolic dysfunction-associated steatotic liver disease (MASLD) in adults with HIV infection in India has not been explored to date.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!