Hepatocellular carcinoma (HCC) is considered as a complex liver disease and ranked as the eighth-highest mortality rate with a prevalence of 2.4% in Malaysia. Magnetic resonance imaging (MRI) has been acknowledged for its advantages, a gold technique for diagnosing HCC, and yet the false-negative diagnosis from the examinations is inevitable. In this study, 30 MR images from patients diagnosed with HCC is used to evaluate the robustness of semi-automatic segmentation using the flood fill algorithm for quantitative features extraction. The relevant features were extracted from the segmented MR images of HCC. Four types of features extraction were used for this study, which are tumour intensity, shape feature, textural feature and wavelet feature. A total of 662 radiomic features were extracted from manual and semi-automatic segmentation and compared using intra-class relation coefficient (ICC). Radiomic features extracted using semi-automatic segmentation utilized flood filling algorithm from 3D-slicer had significantly higher reproducibility (average ICC = 0.952 ± 0.009, < 0.05) compared with features extracted from manual segmentation (average ICC = 0.897 ± 0.011, > 0.05). Moreover, features extracted from semi-automatic segmentation were more robust compared to manual segmentation. This study shows that semi-automatic segmentation from 3D-Slicer is a better alternative to the manual segmentation, as they can produce more robust and reproducible radiomic features.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8468357PMC
http://dx.doi.org/10.3390/diagnostics11091573DOI Listing

Publication Analysis

Top Keywords

semi-automatic segmentation
20
features extracted
20
radiomic features
16
manual segmentation
12
features
9
segmentation
9
hepatocellular carcinoma
8
carcinoma hcc
8
features extraction
8
extracted manual
8

Similar Publications

Purpose: Contrast-enhanced CT (CECT) may be performed immediately following microwave liver ablation for assessment of ablative margins. However, practices and protocols vary among institutions. Here, we compare a standardized bolus-tracked biphasic CECT protocol and compare this with a single venous phase fixed delay protocol for ablation zone (AZ) assessment.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the accuracy of three commercial and one open-source deep learning solutions for automatic tooth segmentation in cone beam computed tomography (CBCT) images from patients with multiple dental impactions.
  • The analysis included 20 CBCT scans and compared expert-generated segmentations with those produced by the deep learning tools, utilizing metrics like Dice similarity coefficient (DSC) and normalized surface distance (NSD) for evaluation.
  • Overall, while all methods demonstrated good efficiency with average NSD around 95%, two solutions (Diagnocat and DentalSegmentator) outperformed others, highlighting variability in accuracy depending on the complexity of the cases.
View Article and Find Full Text PDF

Background: The inferior alveolar canal (IAC) is a fundamental mandibular structure. It is important to conduct a precise pre-surgical evaluation of the IAC to prevent complications. Recently, the use of artificial intelligence (AI) has demonstrated potential as a valuable tool for dentists, particularly in the field of oral and maxillofacial radiology.

View Article and Find Full Text PDF

An automatic approach to detect skin cancer utilizing active infrared thermography.

Heliyon

December 2024

Department of Electrical Engineering, Universidad de Concepción, Edmundo Larenas 219, Concepción, 4030000, Biobío, Chile.

Skin cancer is a growing global concern, with cases steadily rising. Typically, malignant moles are identified through visual inspection, using dermatoscopy and patient history. Active thermography has emerged as an effective method to distinguish between malignant and benign lesions.

View Article and Find Full Text PDF

Artificial intelligence-derived coronary artery calcium scoring saves time and achieves close to radiologist-level accuracy accuracy on routine ECG-gated CT.

Int J Cardiovasc Imaging

December 2024

Division of Cardiothoracic Radiology, Department of Radiology and Radiological Science, Medical University of South Carolina, Clinical Science Building, 96 Jonathan Lucas Street, Suite 210, MSC 323, Charleston, SC, 29425, USA.

Artificial Intelligence (AI) has been proposed to improve workflow for coronary artery calcium scoring (CACS), but simultaneous demonstration of improved efficiency, accuracy, and clinical stability have not been demonstrated. 148 sequential patients who underwent routine calcium-scoring computed tomography were retrospectively evaluated using a previously validated AI model (syngo. CT CaScoring VB60, Siemens Healthineers, Forscheim, Germany).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!