Precision swine production can benefit from autonomous, noninvasive, and affordable devices that conduct frequent checks on the well-being status of pigs. Here, we present a remote monitoring tool for the objective measurement of some behavioral indicators that may help in assessing the health and welfare status-namely, posture, gait, vocalization, and external temperature. The multiparameter electronic sensor board is characterized by laboratory measurements and by animal tests. Relevant behavioral health indicators are discussed for implementing machine learning algorithms and decision support tools to detect animal lameness, lethargy, pain, injury, and distress. The roadmap for technology adoption is also discussed, along with challenges and the path forward. The presented technology can potentially lead to efficient management of farm animals, targeted focus on sick animals, medical cost savings, and less use of antibiotics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8466302PMC
http://dx.doi.org/10.3390/ani11092665DOI Listing

Publication Analysis

Top Keywords

monitoring tool
8
technology adoption
8
behavioral monitoring
4
tool pig
4
pig farmers
4
farmers ear
4
ear tag
4
tag sensors
4
sensors machine
4
machine intelligence
4

Similar Publications

Background: We investigated the consistency and accuracy of the Index of Consciousness (IoC) and the Bispectral Index (BIS) in monitoring the sedative effect of ciprofol during the induction of general anesthesia. There is extensive literature that reports good consistency and correlations between the IoC1 and the BIS in reflecting the sedation levels induced by propofol and sevoflurane but not by ciprofol.

Objective: The aim was to compare the consistency and accuracy of the IoC and BIS in monitoring the sedative effect of ciprofol during the induction of general anesthesia.

View Article and Find Full Text PDF

Co-design in healthcare with and for First Nations Peoples of the land now known as Australia: a narrative review.

Int J Equity Health

January 2025

Discipline of Podiatry, School of Health Sciences, Western Sydney University, Dharawal Country, Campbelltown, NSW, Australia.

Increasing use of co-design concepts and buzzwords create risk of generating 'co-design branded' healthcare research and healthcare system design involving insincere, contrived, coercive engagement with First Nations Peoples. There are concerns that inauthenticity in co-design will further perpetuate and ingrain harms inbuilt to colonial systems.Co-design is a tool that inherently must truly reposition power to First Nations Peoples, engendering both respect and ownership.

View Article and Find Full Text PDF

The I38T substitution in the influenza virus polymerase-acidic (PA) subunit is a resistance marker of concern for treatment with the antiviral baloxavir marboxil (BXM). Thus, monitoring PA/I38T mutations is of clinical importance. Here, we developed three rapid and sensitive assays for the detection and monitoring of the PA/I38T mutation.

View Article and Find Full Text PDF

Seasonal monitoring of forage C:N:ADF ratio in natural rangeland using remote sensing data.

Environ Monit Assess

January 2025

Department of Plant and Soil Sciences, University of Pretoria, Hatfield, 0001, Pretoria, South Africa.

In recent decades, natural rangelands have emerged as vital sources of livelihood and ecological services, particularly in Southern Africa, supporting communities in developing regions. However, the escalating global demand for food, driven by a growing human population, has led to the extensive expansion of cultivated areas, resulting in continuous nutrient leaching in rangelands. To ensure the long-term viability of these ecosystems, there is a need to develop effective approaches for managing and monitoring the seasonality of forage quality.

View Article and Find Full Text PDF

Ultra-high field MRI with parallel transmission (pTx) provides a powerful neuroimaging tool with potential application in paediatrics. The use of pTx, however, necessitates a dedicated local specific absorption rate (SAR) management strategy, able to predict and monitor the peak local SAR (pSAR). In this work, we address the pSARassessment for an in-house built 7 Tesla 16Tx32Rx pediatric head coil, using the concept of Virtual Observation Points (VOPs) for SAR estimation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!