HDL-mediated cholesterol efflux capacity (CEC) may protect against cardiovascular disease. However, CEC assays are not standardized, hampering their application in large cohorts and comparison between studies. To improve standardization, we systematically investigated technical differences between existing protocols that influence assay performance that have not been previously addressed. CEC was measured in 96-well plates using J774A.1 macrophages labeled with BODIPY-cholesterol and incubated for 4 h with 2% apolipoprotein B-depleted human serum. The time zero method, which calculates CEC using control wells, and the per-well method, which calculates CEC based on the actual content of BODIPY-cholesterol in each well, were compared in 506 samples. We showed that the per-well method had a considerably lower sample rejection rate (4.74% vs. 13.44%) and intra-assay (4.48% vs. 5.28%) and interassay coefficients of variation (two controls: 7.85%, 9.86% vs. 13.58%, 15.29%) compared with the time zero method. Correction for plate-to-plate differences using four controls on each plate also improved assay performance of both methods. In addition, we observed that the lysis reagent used had a significant effect. Compared with cholic acid, lysis with sodium hydroxide results in higher (P = 0.0082) and Triton X-100 in lower (P = 0.0028) CEC values. Furthermore, large cell seeding errors (30% variation) greatly biased CEC for both referencing methods (P < 0.0001) as measured by a resazurin assay. In conclusion, lysis reagents, cell numbers, and assay setup greatly impact the quality and reliability of CEC quantification and should be considered when this method is newly established in a laboratory.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8521207 | PMC |
http://dx.doi.org/10.1016/j.jlr.2021.100125 | DOI Listing |
Int J Legal Med
January 2025
Division of Forensic Medicine and Toxicology, Department of Pathology, Faculty of Health Science, University of Cape Town, Cape Town, South Africa.
The ForenSeq™ DNA Signature Prep kit has not been thoroughly tested with crude buccal swab lysates in large-scale population studies using massively parallel sequencing (MPS). Commonly used lysis buffers for swabs intending to undergo direct polymerase chain reaction (PCR) are SwabSolution™ and STR GO! Lysis Buffers, and these have been successfully used to generate population data using capillary electrophoresis (CE) systems. In this study, we investigated the performance and optimisation of SwabSolution™ and STR GO! lysates with the ForenSeq™ DNA Signature Prep workflow and addressed the challenge of failed MPS profiles in initial trials.
View Article and Find Full Text PDFSci Total Environ
January 2025
Environmental Science and Engineering Program, Guangdong Technion-Israel Institute of Technology, 241 Daxue Road, Shantou, Guangdong 515063, China.
Extracellular polymeric substances (EPS) significantly influence the properties and performance of waste activated sludge. Various pretreatment protocols with different extraction efficiency and characteristics of EPS have been reported, which markedly impact subsequent treatment and disposal of sewage sludge. This study systematically assesses the EPS properties from twelve extraction pretreatment methods.
View Article and Find Full Text PDFJ Med Virol
December 2024
Beijing Institute of Hepatology/Beijing Youan Hospital, Capital Medical University, Beijing, People's Republic of China.
Hepatitis E virus (HEV) poses a serious threat to both public health and animal food safety, thereby highlighting the demands for rapid, sensitive, and easy-to-use detection. This study aimed to develop a One-Pot assay using CRISPR/Cas13a for detecting HEV RNA, suitable for point-of-care testing (POCT) in resource-limited settings. CRISPR/Cas13a combined with reverse transcription polymerase chain reaction (RT-PCR) and reverse transcription recombinase-aided amplification (RT-RAA) was applied to a One-Pot assay device.
View Article and Find Full Text PDFBiol Methods Protoc
October 2024
One Health Research Group, Facultad de Ciencias de la Salud, Universidad de Las Américas, Quito, 170124, Ecuador.
We present a rapid high-throughput DNA extraction method for use with EDTA-anticoagulated blood using silicon dioxide (SiO) powder in a guanidine-HCl solution, hereinafter referred to as "Glassmilk." The method utilizes a 96-well deep-well plate, enabling DNA extraction from 96 samples in under 3 h. The method integrates cell lysis, washing, elution, and DNA storage within the same well, eliminating the need for DNA transfer.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Dhaka, Dhaka, 1000, Bangladesh.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!