Whole-body plethysmography (WBP) is the gold standard for measuring lung volume, but its clinical application is limited as it requires expensive equipment and is not simple to use. Studies have shown that the single-breath helium dilution (SBHD) method, which is commonly used in clinical practice, significantly underestimates lung volume in patients with obstructive lung disease (OLD). By comparing the differences in lung volume measured using SBHD and WBP, we aimed to establish a correction equation for the SBHD method to determine the total lung volume in patients with OLD of different severities. From 628 patients with OLD simultaneously subjected to SBHD and WBP, 407 patients enrolled between January 2018 and November 2019 were in the training group and 221 enrolled between December 2019 and December 2020 were in the prospective verification cohort. The multiple linear regression equation was used for data in the training group to establish a correction equation for SBHD to determine the total lung volume, and this was validated in the prospective validation cohort. There was a moderate positive correlation between total lung capacity (TLC) determined using the SBHD [TLC (SBHD)] and WBP methods [TLC (WBP)] (r = 0.701; < 0.05), and the differences between TLC (SBHD) and TLC (WBP) (ΔTLC) were related to the severity of obstruction. As the severity of obstruction increased, the TLC was underestimated by the SBHD method. We established the following correction equation: () () = -0.669 + 0.756*()() - 0.047* +0.039* ()-0.009*()(r2 = 0.753 and adjusted r2 = 0.751). Next, we validated this equation in the validation cohort. With the correction equation, no statistical difference was observed between TLC (adjusted SBHD) and TLC (WBP) among the obstruction degree groups ( > 0.05). The SBHD method is correlated with WBP to measure the total lung volume, but the SBHD method presents limitations in determining the total lung volume in patients with obstructive lung disease. Here, we established an effective and reliable correction equation in order to accurately assess the total lung volume of patients with OLD using the SBHD method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8455942 | PMC |
http://dx.doi.org/10.3389/fmed.2021.737360 | DOI Listing |
Life (Basel)
January 2025
National Pulmonary Hypertension Service, Hammersmith Hospital, Imperial College NHS Trust, DuCane Road, London W12 0HS, UK.
Background: Stroke volume index (SVI) is an important prognostic parameter in pulmonary arterial hypertension (PAH). The direct Fick (DF) method represents the gold standard for measuring it. Indirect Fick (IF) and thermodilution (TD) are simpler and widely used alternatives.
View Article and Find Full Text PDFLife (Basel)
December 2024
Division of Thoracic Surgery, IRCCS Azienda Ospedaliero Universitaria Di Bologna, Via Albertoni 15, 40138 Bologna, Italy.
(1) Background: Ex Vivo Lung Perfusion (EVLP) is a technique designed to assess and recondition marginal lungs, potentially expanding the donor pool and improving transplant outcomes (2) Methods: This retrospective study evaluated lung transplantation outcomes after EVLP. Donor lungs were assessed using the Toronto protocol, with data on hemodynamics, gas exchange, and perfusion parameters collected and analyzed. Post-transplant complications and survival rates were also examined.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Radiotherapy, Research Centre for Digital Medicine, VUB-UZ Brussel, 1090 Brussels, Belgium.
: Inadequate dosing and respiratory motion contribute to local recurrence for oligometastatic disease (OMD). While short-term LC rates are well-documented, data on long-term LC remain limited. This study investigated long-term LC after stereotactic body radiotherapy (SBRT), using respiratory motion management techniques.
View Article and Find Full Text PDFBiomedicines
January 2025
Digestive Diseases and Surgery Institute, HPB and Transplant Surgery, Cleveland Clinic Foundation, Cleveland, OH 44195, USA.
Solid-organ malignancies represent a significant disease burden and remain one of the leading causes of death globally. In the past few decades, the rapid evolution of imaging modalities has shifted the paradigm towards image-based precision medicine, especially in the care of patients with solid-organ malignancies. Metabolic tumor volume (MTV) is one such semi-quantitative parameter obtained from positron emission tomography (PET) imaging with F-fluorodeoxyglucose (FDG) that has been shown to have significant implications in the clinical oncology setting.
View Article and Find Full Text PDFRespir Res
January 2025
National Heart and Lung Institute, Imperial College London, London, UK.
Background: Systemic sclerosis (SSc) is a rare connective tissue disease associated with rapidly evolving interstitial lung disease (ILD), driving its mortality. Specific imaging-based biomarkers associated with the evolution of lung disease are needed to help predict and quantify ILD.
Methods: We evaluated the potential of an automated ILD quantification system (icolung) from chest CT scans, to help in quantification and prediction of ILD progression in SSc-ILD.