Polymethylmethacrylate (PMMA) is a commonly used substrate in vertebroplasty procedures. Well-known for its dependable strength and relative lack of toxic side effects, PMMA administration is useful for the stabilization of vertebral bodies in the setting of common spinal pathologies such as osteoporosis. Unfortunately, as the popularity of vertebroplasty has increased, so has the incidence of a potentially lethal complication of the procedure, PMMA pulmonary embolism. Extravasation of PMMA from the vertebral body into the adjacent vasculature can provide a route through which PMMA may travel until it becomes lodged in the pulmonary vasculature, thereby forming a PMMA pulmonary embolism. While the vast majority of PMMA embolism cases are relatively mild, others are severe and demand swift recognition and potentially life-saving intervention. Despite the increasing incidence of PMMA embolism, a clear algorithm for management does not yet exist. Controversy abounds regarding the most effective strategies to diagnose and manage patients with PMMA embolism. Described is a case of delayed diagnosis of a PMMA embolism in a patient who underwent percutaneous vertebroplasty for an osteoporotic vertebral body fracture. Multiple visits to the emergency department (ED) for chest discomfort or cough after the vertebroplasty eventually led to cross-sectional imaging that revealed the diagnosis. Her acute symptoms resolved with conservative management. Given that her final outcome was positive with no long-term morbidity, the aim of this report is to explore the current treatment algorithms for PMMA embolism and to consider whether or not this patient would have been managed differently had the correct diagnosis been uncovered earlier.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451524PMC
http://dx.doi.org/10.7759/cureus.17314DOI Listing

Publication Analysis

Top Keywords

pmma embolism
16
pulmonary embolism
12
pmma
10
pmma pulmonary
8
vertebral body
8
embolism
7
vertebroplasty
5
polymethylmethacrylate pulmonary
4
embolism vertebroplasty
4
vertebroplasty polymethylmethacrylate
4

Similar Publications

A 78-year-old woman with vertebral compression fractures (VCFs) and chronic back pain was the subject of this case study. To treat symptomatic VCFs, less invasive procedures such as balloon kyphoplasty and vertebroplasty were developed. Vertebroplasty involves injecting polymethylmethacrylate (PMMA) into the vertebral body to mechanically stabilize it.

View Article and Find Full Text PDF

Background: The prevalence of osteoporosis is escalating alongside an aging global population, increasing the demand for spinal surgeries, including those necessitating cement augmentation for enhanced construct stability.

Objective: This article delves into the nuanced application of cement augmentation techniques for pedicle screws and vertebral body replacements (VBR), aimed at optimizing surgical outcomes in osteoporotic spines.

Method: Drawing from a comprehensive literature review according to important clinical and biomechanical studies and the authors' clinical experiences, we elucidate strategies to mitigate complications and improve surgical efficacy.

View Article and Find Full Text PDF

Percutaneous vertebroplasty (PVP) is a surgical procedure that involves injecting polymethylmethacrylate (PMMA) bone cement into the diseased vertebrae to rapidly relieve pain and strengthen the vertebrae. We reported a 73-year-old patient who underwent percutaneous vertebroplasty (PVP) surgery for thoracolumbar vertebral compression fracture. After the surgery, the patient experienced symptoms such as chest tightness and dyspnea.

View Article and Find Full Text PDF

An older woman developed dyspnea after instrumented lumbar spinal fusion surgery. During clinical work-up, a chest radiography revealed a U-shaped object within the cardiac silhouette. Further imaging confirmed that the object was entrapped in the tricuspid subvalvular apparatus.

View Article and Find Full Text PDF

Background: The prevalence of osteoporosis is escalating alongside an aging global population, increasing the demand for spinal surgeries, including those necessitating cement augmentation for enhanced construct stability.

Objective: This article delves into the nuanced application of cement augmentation techniques for pedicle screws and vertebral body replacements (VBR), aimed at optimizing surgical outcomes in osteoporotic spines.

Method: Drawing from a comprehensive literature review according to important clinical and biomechanical studies and the authors' clinical experiences, we elucidate strategies to mitigate complications and improve surgical efficacy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!