A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the sensitivity of patient-reported outcomes for detecting the benefit of biologics in severe asthma. | LitMetric

BackgroundThe sensitivity of patient-reported outcomes (PROs) to detect the effects of treatment change depends on the match between the change in items of the PRO and the change that takes place in a sample of people. The aim of this study is to compare the sensitivity of different PROs in detecting changes following the initiation of biologic treatment in asthma. Patients starting a biologic treatment as part of clinical care completed the Asthma Control Questionnaire (ACQ-6), the Severe Asthma Questionnaire (SAQ and SAQ-global scores) and the EQ5D (EQ-5D-5L and EQ5D-VAS) at baseline. They completed the ACQ-6, SAQ, SAQ-global and a retrospective global rating of change (GRoC) scale at weeks 4, 8 and 16 and completed the EQ-5D-5L and EQ5D-VAS at week 16. The SAQ-global and EQ5D-VAS differ but both are single item 100-point questions. Sensitivity was measured by Cohen's D effect size at each of the three time points. 110 patients were recruited. Depending on the time of assessment, effect size varied between 0.45 and 0.64 for the SAQ, between 0.50 and 0.77 for the SAQ-global; between 0.45 and 0.69 for ACQ-6; between 0.91 and 1.22 for GRoC; 0.32 for EQ-5D-5L and 0.49 for EQ5D-VAS. The sensitivity to change of a questionnaire varies with the time of measurement. The three asthma-specific prospective measures (SAQ, SAQ-global and ACQ-6) have similar sensitivity to change. The single-item EQ5D-VAS was less sensitive than the asthma specific measures and less sensitive than the single-item SAQ-global. The EQ-5D-5L was least sensitive.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8477679PMC
http://dx.doi.org/10.1177/14799731211043530DOI Listing

Publication Analysis

Top Keywords

saq saq-global
12
sensitivity patient-reported
8
patient-reported outcomes
8
severe asthma
8
biologic treatment
8
eq-5d-5l eq5d-vas
8
sensitivity change
8
change
6
saq-global
6
asthma
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!