A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical comparison of locking and non-locking patient-specific mandibular reconstruction plate using finite element analysis. | LitMetric

Biomechanical comparison of locking and non-locking patient-specific mandibular reconstruction plate using finite element analysis.

J Mech Behav Biomed Mater

Department of Biomedical Sciences, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Kapucijnenvoer 33, 3000, Leuven, Belgium.

Published: December 2021

Patient-specific mandibular reconstruction plate (PSMRP), as one of the patient-specific implants (PSIs), offers a host of benefits to mandibular reconstruction. Due to the limitation of fabricating screw hole threads in the PSMRP, 3D printed PSMRP is applied to the non-locking system directly in the mandibular reconstruction with bone graft regardless of the locking system. Since the conventional manual-bending reconstruction plate (CMBRP) provides better fixation in the locking system, it needs to be validated whether the locking PSMRP performs better than the non-locking PSMRP in the patient-specific mandibular reconstruction. Thereupon, the purpose of this study was to compare the biomechanical behavior between the locking and non-locking PSMRP. Finite element analysis (FEA) was used to conduct the biomechanical comparison between the locking PSMRP and non-locking PSMRP by simulating the momentary incisal clenching through static structural analysis. Mandible was reconstructed through the virtual surgical planning, and subsequently a 3D model of mandibular reconstruction assembly, including reconstructed mandible, PSMRP, and fixation screws, was generated and meshed for the following FEA simulations. In the form of equivalent von Mises stress, equivalent elastic strain, and total deformation, the locking PSMRP demonstrated its higher strengths of preferable safety, desirable flexibility, and anticipated stability compared with the non-locking PSMRP, indicated by much lower maximum stress, lower maximum strain and equivalent displacement. Locking PSMRP/screw system provides a better fixation effect to the patient-specific mandibular reconstruction than the non-locking one as a result of its productive fixation nature. FEA plays a paramount role in pre-validating the design of PSMRP through the biomechanical behavior evaluation in static structural analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2021.104849DOI Listing

Publication Analysis

Top Keywords

mandibular reconstruction
28
patient-specific mandibular
16
non-locking psmrp
16
reconstruction plate
12
psmrp
12
locking psmrp
12
biomechanical comparison
8
locking
8
comparison locking
8
locking non-locking
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!