Background: Patients with heart failure undergoing cardiac resynchronization therapy with or without defibrillator function may exhibit recovery of left ventricular ejection fraction (LVEF) during follow-up. Mechanical dispersion (MD; the SD of time to peak longitudinal strain by two-dimensional speckle-tracking echocardiography) is a known predictor of life-threatening ventricular arrhythmias (VAs). Relationships among LVEF recovery, changes in MD, and incidence of VA are still not extensively investigated.

Methods: In this retrospective study, recipients of cardiac resynchronization therapy defibrillation (n = 183) or implantable cardioverter-defibrillators only (n = 87) underwent conventional and speckle-tracking echocardiography, both at baseline and after 10 to 12 months, and were followed clinically. Both a ≥10% increase in LVEF and a final LVEF > 35% defined echocardiographic response (Echo). Reduction in MD ≥10 msec defined MD response (MD). Risk for appropriate implantable cardioverter-defibrillator therapy for VAs was assessed using a multivariable Cox hazard model.

Results: The prevalence of Echo+ and MD+ was 39% and 46%, respectively. During follow-up (49.8 ± 33.5 months), 74 VA events occurred. The incidence rate (per 100 patient-years) of VAs was lowest in the Echo+/MD+ group (1.66%; 95% CI, 0.69%-3.99%), highest in the Echo-/MD- group (12.8%; 95% CI, 9.53%-17.2%; P < .0001), and intermediate in the Echo-/MD+ (5.5%; 95% CI, 3.3%-9.4%) or Echo+/MD- (5.3%; 95% CI, 3.0%-9.4%) group. Multivariable analysis showed that higher MD at follow-up (>71.4 msec) was associated with VAs independent of whether final LVEF was below or above the guideline-reported cutoff of 35% (P < .05).

Conclusions: Among ICD recipients, improvements in both left ventricular function and MD are associated with reduced risk for VAs. In patients whose follow-up LVEFs improved to >35%, risk for VAs, although substantially decreased, remained elevated in the presence of still elevated MD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2021.09.009DOI Listing

Publication Analysis

Top Keywords

cardiac resynchronization
12
resynchronization therapy
12
speckle-tracking echocardiography
12
ventricular arrhythmias
8
therapy defibrillation
8
implantable cardioverter-defibrillator
8
left ventricular
8
ventricular ejection
8
ejection fraction
8
final lvef
8

Similar Publications

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF
Article Synopsis
  • Cardiac resynchronization therapy (CRT) improves functional mitral regurgitation (FMR) by coordinating heart muscle segments, especially between papillary muscles, beyond just boosting left ventricular (LV) performance.
  • Eighteen patients with dilated cardiomyopathy underwent tests to measure heart function, and biventricular pacing showed a significant reduction in mitral regurgitation despite some patients showing no change in LV pressure.
  • The study concludes that CRT effectively lowers FMR independently of LV systolic function improvements, highlighting the importance of understanding its mechanisms for better treatment outcomes.
View Article and Find Full Text PDF
Article Synopsis
  • Cardiac resynchronization therapy (CRT) is effective for treating heart failure but is under-researched in patients with common comorbidities like atrial fibrillation (AF).
  • The SMART registry enrolled 2035 patients to assess CRT response based on clinical outcomes over 12 months, focusing on factors like all-cause mortality, hospitalizations, and quality of life.
  • Results showed 58.9% of patients improved, but factors like age, AF, and diabetes were linked to lower CRT responsiveness, with patients having AF experiencing higher rates of hospitalizations and mortality compared to those in normal rhythm.
View Article and Find Full Text PDF

Deep Septal Pacing for Pacemaker-Induced Cardiomyopathy.

Pacing Clin Electrophysiol

December 2024

Servei de Cardiologia, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Barcelona, España.

Introduction: Right ventricular (RV) pacing can impair left ventricular function and cause heart failure, known as pacing-induced cardiomyopathy (PICM). Upgrade to cardiac resynchronization (CRT) is its usual treatment; recently left bundle branch area pacing (LBBAP) has emerged as a potential alternative. Deep septal pacing (DSP), a simplified alternative to LBBAP, is still able to achieve narrower paced QRS than during conventional RV pacing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!