Objective: To improve the accuracy of drilling during the repair of sacroiliac luxations (SILs) with a 3D-printed patient-specific drill guide (3D-GDT) compared to free-hand drilling technique (FHDT).
Study Design: Blinded, randomized, prospective ex vivo study.
Sample Population: Sixteen canine cadavers (20-25 kg).
Methods: Dorsal, bilateral SILs were created. Pelvic CT was performed pre- and post-drilling. The FHDT was drilled followed by 3D-GDT. CT and 3D measurements of craniocaudal and dorsoventral angles were compared between FHDT and 3D-GDT, as well as deviations of entry and exit points relative to optimal trajectory.
Results: Mean craniocaudal and dorsoventral angles for both CT- and 3D-measured 3D-GDT (CT 4.2 ± 3.9° and 3.9 ± 3.2°, respectively; 3D 5.1 ± 5.1° and 2.8 ± 2.3°, respectively p = .0006) were lower compared to FHDT (CT 11.8 ± 4.0°, p < .0001 and 8.9 ± 6.1°, p = .01; 3D 12.4 ± 5.9°, p = .0006 and 5.3 ± 5.24°, p = .05). Entry dorsoventral and end craniocaudal, dorsoventral, and 3D linear deviations were reduced with 3D-GDT. Sacral corridor disruption was present in 20% (3/15) for FHDT compared with 0% for 3D-GDT. CT and 3D analyses were in strong agreement (r = 0.77).
Conclusion: Deviations of drill trajectories were minimized relative to optimal trajectories with 3D-GDT compared to FHDT in the dorsoventral and craniocaudal planes.
Clinical Significance: The use of 3D-GDT improves accuracy of sacral drilling compared with FHDT in canine cadavers. These results justify further evaluation in a clinical, prospective study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vsu.13721 | DOI Listing |
J Dent Sci
December 2024
Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Chulalongkorn University, Bangkok, Thailand.
Background/purpose: Many designs of static computer-assisted implant surgery (sCAIS) are available for clinician to achieve proper implant position. However, there were not any studies that approached the design alone to evaluate whether sleeve-in-sleeve or sleeve-on-drill design provided most accuracy implant position. The purpose of this study was to investigate the precision of implant placement with sleeve-in-sleeve and sleeve-on-drill static computer assisted implant surgery (sCAIS) designs.
View Article and Find Full Text PDFJ Dent Sci
December 2024
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Background/purpose: Computer-assisted implant surgery (CAIS) is increasingly performed to reduce deviations in implant position. Dynamic CAIS or navigation systems provide instant display of implant drilling instruments and patient positions directly on the computer monitor. Augmented reality (AR) technology allows operators to visualize real-time information projected onto the lenses of AR glasses.
View Article and Find Full Text PDFVet Surg
January 2025
Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.
Objective: To evaluate the accuracy of ventral slot creation in canine cadavers with a three-dimensional (3D)-printed drill guide compared to the freehand technique.
Study Design: Ex vivo study.
Sample Population: Eight canine cadavers (23.
Dent Res J (Isfahan)
December 2024
Department of Periodontology, Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran.
Background: Chronic apical periodontitis (AP) may influence the outcome of root canal treatment. Thus, it is important to diagnose AP using the best method available. This research was done to compare the diagnostic accuracy of parallel periapical radiography (PR) and different field of views (FOVs) of cone-beam computed tomography (CBCT).
View Article and Find Full Text PDFMusculoskelet Surg
January 2025
Department of Trauma and Orthopaedic Surgery, Barts Health NHS Trust, Royal London Hospital, London, E11BB, England.
3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!