AI Article Synopsis

  • The study aimed to identify risk factors associated with children whose ventricular sizes remained unchanged during shunt malfunctions, presenting a unique diagnostic challenge.
  • It analyzed data from 450 children with shunted hydrocephalus and found that factors like having a frontal shunt, a programmable valve, and a larger baseline frontal-occipital horn ratio (FOR) correlated with unchanged ventricles.
  • The findings suggest that certain characteristics, including the type of shunt and patient history, can help predict when ventricular size won't change despite shunt issues.

Article Abstract

Objective: Children whose ventricles do not change during shunt malfunction present a diagnostic dilemma. This study was performed to identify risk factors for unchanged ventricular size at shunt malfunction.

Methods: This retrospective 1:1 age-matched case-control study identified children with shunted hydrocephalus who underwent shunt revision with intraoperative evidence of malfunction at one of the three participating institutions from 1997 to 2019. Cases were defined as patients with a change of < 0.05 in the frontal-occipital horn ratio (FOR) between malfunction and baseline, and controls included patients with FOR changes ≥ 0.05. The presence of infection, abdominal pseudocyst, pseudomeningocele, or wound drainage and lack of baseline cranial imaging at the time of malfunction warranted exclusion.

Results: Of 450 included patients, 60% were male, 73% were Caucasian, and 67% had an occipital shunt. The median age was 4.3 (IQR 0.97-9.21) years at malfunction. On univariable analysis, unchanged ventricles at malfunction were associated with a frontal shunt (41% vs 28%, p < 0.001), programmable valve (17% vs 9%, p = 0.011), nonsiphoning shunt (85% vs 66%, p < 0.001), larger baseline FOR (0.44 ± 0.12 vs 0.38 ± 0.11, p < 0.001), no prior shunt infection (87% vs 76%, p = 0.003), and no prior shunt revisions (68% vs 52%, p < 0.001). On multivariable analysis with collinear variables removed, patients with a frontal shunt (OR 1.67, 95% CI 1.08-2.70, p = 0.037), programmable valve (OR 2.63, 95% CI 1.32-5.26, p = 0.007), nonsiphoning shunt at malfunction (OR 2.76, 95% CI 1.63-4.67, p < 0.001), larger baseline FOR (OR 3.13, 95% CI 2.21-4.43, p < 0.001), and no prior shunt infection (OR 2.34, 95% CI 1.27-4.30, p = 0.007) were more likely to have unchanged ventricles at malfunction.

Conclusions: In a multicenter cohort of children with shunt malfunction, those with a frontal shunt, programmable valve, nonsiphoning shunt, baseline large ventricles, and no prior shunt infection were more likely than others to have unchanged ventricles at shunt failure.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2021.6.PEDS2125DOI Listing

Publication Analysis

Top Keywords

shunt
17
unchanged ventricles
16
shunt malfunction
16
prior shunt
16
frontal shunt
12
programmable valve
12
nonsiphoning shunt
12
shunt infection
12
malfunction
9
risk factors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!