Comparison of mechanical properties between Nice knot, Modified Nice knot, and surgeon's knot.

Clin Biomech (Bristol)

Midwest Orthopaedics at Rush, Rush University Medical Center, Chicago, IL, United States of America. Electronic address:

Published: December 2021

Background: The success of surgical repairs rely on the effectiveness and integrity of the surgical knots used to secure the repair. The purpose of this study is to examine and compare the performance of the Nice knot, the modified Nice knot, and a commonly used combination of surgeons' and square knots with respect to cyclic loading and load-to-failure usiflueng a high-strength suture composed of ultra-high molecular weight polyethylene in the hands of experienced surgeons.

Methods: Two experienced surgeons threw 3 different knot types 9 times, consisting of the Nice knot, modified Nice knot, and a surgeon's knot utilizing Ultrabraid #2 sutures. Each knot was subject to cyclic loading and load to failure testing.

Findings: Both surgeons had similar displacement data for the surgeon's knot, while the identity of the surgeon impacted displacement for the Nice knot (p = 0.03) and the modified Nice knot (p = 0.0002). The load to failure for the modified Nice knot (p < 0.001) and the Nice knot (p = 0.001) were significantly impacted by the surgeon tying the knot, while the surgeon's knot was not. Specimens failed where the sutures passed through the loop at the "base" of the knot.

Interpretations: The strength and integrity of complex surgical knots are variable between surgeons. While the proposed Modified Nice Knot has a theoretical advantage because the half hitches reinforce the primary knot, in load to failure testing both the Modified Nice Knot and the Nice Knot failed where the suture passed through the loop in the primary knot.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2021.105486DOI Listing

Publication Analysis

Top Keywords

nice knot
36
modified nice
20
knot
14
knot modified
12
surgeon's knot
12
nice
9
knot surgeon's
8
cyclic loading
8
load failure
8
modified
5

Similar Publications

Introduction: Mastering paediatric laparoscopic surgery competency (PLSC) is technically challenging. The present study aimed to determine whether the inter-academic PLSC degree (IAD_PLSC) practical training program enables trainees to improve their skills.

Methods: This retrospective study included trainees enrolled in the IAD_PLSC program in 2021 and 2022 which included two separate 12 h-sessions.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness of using an Endobutton plate combined with high-strength suture Nice knot fixation for treating distal clavicular fractures along with coracoclavicular ligament injuries.
  • It involved a retrospective analysis of 43 patients, comparing two treatment methods: the experimental group (high-strength Nice knot suture fixation) and a control group (acromioclavicular Kirschner wire fixation), over an average follow-up period of about 20 months.
  • Results showed that while the experimental group had significantly faster bone healing times, there were no notable differences in coracoclavicular space increase, demographic data, or shoulder function improvement between the two groups.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the effectiveness of Nice knot-assisted fixation in treating comminuted and displaced clavicle fractures compared to traditional surgical methods.
  • A systematic literature search identified 11 relevant studies with a total of 754 patients, analyzing outcomes such as healing time, blood loss, and functional scores.
  • Results indicated that Nice knot-assisted fixation led to shorter operative times, less blood loss, faster fracture healing, and improved functional outcomes, though it did not significantly affect hospitalization duration or complications compared to traditional methods.
View Article and Find Full Text PDF
Article Synopsis
  • - This study explores the effectiveness of using Kirschner wire combined with an improved Nice knot method for fixing displaced and comminuted clavicle fractures in a surgical setting, comparing it against traditional reduction methods.
  • - Researchers analyzed data from 210 patients, comparing outcomes like operation time, blood loss, pain levels, healing time, and overall satisfaction among different treatment groups.
  • - Results indicated that the new method resulted in shorter operation times, less blood loss, lower pain scores, and higher satisfaction compared to standard techniques, suggesting it may be a better choice for these types of fractures.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!