This study investigated the bonding performance of two different types of resin cements to computer-aided design/computer-aided manufacturing (CAD/CAM) composite blocks based on the shear bond strength (SBS) test. A silane-containing self-adhesive resin cement (Panavia SA Cement Universal) and resin luting cement (Block HC Cem) with a primer, were used. Specimens were fabricated from three different types of CAD/CAM composite blocks, and their surfaces were blasted with alumina. Resin cements were bonded to the specimens, and their SBSs were measured after 15 min, 24 h, and after being subjected to thermal cycling for 10,000 and 30,000 cycles. Three-way ANOVA for bond strength revealed that CAD/CAM composite block, resin cement and storage time significantly influenced the SBS values, and the three-way interactions between the evaluated factors, and all the interactions were significant. It was concluded that the bonding performance of resin cements to CAD/CAM composite blocks were material and storage period dependent.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4012/dmj.2021-154 | DOI Listing |
J Dent
January 2025
Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland. Electronic address:
Objective: This study aimed to investigate the resin compounds from CAD-CAM 3D-printed denture resins, focusing on the identification and classification of free monomers and other components. The primary objective was to determine the chemical profile of these 3D-prinding resin materials.
Methods: Four 3D-printed denture resins, two base materials (1: DentaBASE, Asiga Ltd.
J Dent
January 2025
DDS, MS, PhD, Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Brazil. Electronic address:
Objective: To evaluate the influence of different cleaning methods, surface treatments, and aging on the repair bond strength to a CAD/CAM glass-ceramic.
Materials And Methods: Forty-eight lithium disilicate CAD/CAM ceramic blocks were fabricated, sintered, and embedded in acrylic resin. After contamination with human saliva, they were divided according to the factors "Cleaning method" (Control-water/air spray, Air-particle abrasion with AlO, Ivoclean cleaning paste), "Surface treatment" (5% Hydrofluoric acid-HF + Silane, Monobond Etch & Prime-MEP), and "Aging" (thermocycling, no thermocycling).
Anal Chim Acta
February 2025
Department of Pharmaceutical Chemistry, Medical University of Gdansk, Hallera 107, 80-416, Gdansk, Poland.
Background: Benzodiazepine abuse remains a significant public health concern. Current sample preparation methods for benzodiazepine analysis from human serum often involve complex procedures that require large sample volumes and extensive organic solvent use. To address these limitations, this study presents a novel and efficient sample preparation method utilizing 3D-printed sorbent devices.
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
Department of Conservative Dentistry, University Hospital, Ludwig-Maximilians-University, Goethestr. 70, D-80336 Munich, Germany.
Objective: It is hypothesized that the way nano- and micro-hybrid polymer-based composites are structured and cured impacts the way they respond to aging.
Material And Methods: A polymer-ceramic interpenetrating network composite (Vita Enamic/VE), an industrially polymerized (Brillinat CriosST/BC), and an in situ light-cured composite with discrete inorganic fillers (Admira Fusion5/AF5) were selected. Specimens (308) were either cut from CAD/CAM blocks (VE/BC) or condensed and cured in white polyoxymethylene molds (AF5) and subjected to four different aging conditions ( = 22): (a) 24 h storage in distilled water at 37 °C; (b) 24 h storage in distilled water at 37 °C followed by thermal cycling for 10,000 cycles 5/55 °C (TC); (c) TC followed by storage in a 75% ethanol-water solution; and (d) TC followed by a 3-week demineralization/remineralization cycling.
J Esthet Restor Dent
January 2025
Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.
Objective: To conduct a systematic review on the masking ability of subtractively and additively manufactured dental ceramics.
Materials And Methods: The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The electronic search was carried out through MEDLINE, Scopus, and Website of Science databases with a date restriction being from 2001 onwards.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!