Background: The introduction of ultra-high-definition laparoscopic cameras (4K), by providing stronger monocular depth perception, could challenge the existing 3D technology. There are few available studies on this topic, especially in gynaecological setting.

Objectives: Prospective, single institution, randomised clinical trial (NCT04209036).

Materials And Methods: The two laparoscopes utilised were the 0°ULTRA Telescopes with 4K technology and the 0°3D-HD by Olympus. The surgeons were all trainees and in their last year of residency and who had obtained the certificate of first or second level of the Gynaecological Endoscopic Surgical Education and Assessment program - GESEA program. Twenty-nine patients with benign uterine pathology were enrolled.

Main Outcome Measures: To compare if the use three-dimensional (3D) versus ultra-high-definition laparoscopic vision system (4K) for total laparoscopic hysterectomy performed by trainees was associated with a shorter operative time.

Results: The 3D vision system did not prove to be superior to the 4K vision system. Operators reported significantly more vision-related side effects when using 3D than 4K. Completing the GESEA training program was the only factor with a positive and statistically significant impact on the overall time of the procedure, especially when greater dexterity and tissue handling were required.

Conclusions: Neither technology used proved superior to the other, although operators showed a preference for 4K over 3D due to the lower number of visual side effects. Attendance at courses on laparoscopic simulators and training programs allowed trainees to demonstrate excellent surgical skills.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8823275PMC
http://dx.doi.org/10.52054/FVVO.13.3.027DOI Listing

Publication Analysis

Top Keywords

vision system
12
total laparoscopic
8
laparoscopic hysterectomy
8
ultra-high-definition laparoscopic
8
side effects
8
laparoscopic
5
versus total
4
hysterectomy resident
4
resident training
4
training prospective
4

Similar Publications

Over recent years, the retina has been increasingly investigated as a potential biomarker for dementia. A number of studies have looked at the effect of Alzheimer's disease (AD) pathology on the retina and the associations of AD with visual deficits. However, while OCT-A has been explored as a biomarker of cerebral small vessel disease (cSVD), studies identifying the specific retinal changes and mechanisms associated with cSVD are lacking.

View Article and Find Full Text PDF

Background: The post-operative evaluation of trabeculectomy blebs has traditionally relied on subjective clinical grading systems performed at the slit-lamp. This study explores the use of swept source anterior-segment optical coherence tomography (AS-OCT) to objectively measure bleb internal reflectivity and morphology, and to distinguish blebs with surgical success vs. failure.

View Article and Find Full Text PDF

With the rapid development of Internet of Things (IoT) technology, embedded devices in various computer vision scenarios can realize real-time target detection and recognition tasks, such as intelligent manufacturing, automatic driving, smart home, and so on. YOLOv8, as an advanced deep learning model in the field of target detection, has attracted much attention for its excellent detection speed, high precision, and multi-task processing capability. However, since IoT embedded devices typically own limited computing resources, direct deployment of YOLOv8 is a big challenge, especially for real-time detection tasks.

View Article and Find Full Text PDF

MMFW-UAV dataset: multi-sensor and multi-view fixed-wing UAV dataset for air-to-air vision tasks.

Sci Data

January 2025

National Key Lab of Autonomous Intelligent Unmanned Systems, Beijing Institute of Technology, Beijing, 100081, China.

We present an air-to-air multi-sensor and multi-view fixed-wing UAV dataset, MMFW-UAV, in this work. MMFW-UAV contains a total of 147,417 fixed-wing UAVs images captured by multiple types of sensors (zoom, wide-angle, and thermal imaging sensors), displaying the flight status of fixed-wing UAVs of different sizes, appearances, structures, and stabilized flight velocities from multiple aerial perspectives (top-down, horizontal, and bottom-up views), aiming to cover the full-range of perspectives with multi-modal image data. Quality control processes of semi-automatic annotation, manual check, and secondary refinement are performed on each image.

View Article and Find Full Text PDF

Background: Orthokeratology (OK) contact lenses are increasingly prescribed for myopia control but their impact on corneal epithelial immune cells (CEIC) is unclear. This study compares CEIC in OK wearers to soft contact lens (SCL) wearers and non-wearers.

Methods: In vivo confocal microscope images at the corneal central and mid-peripheral subbasal level were evaluated in 18 OK wearers, 18 SCL wearers and 18 non-wearers (mean age 27.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!