A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Paraffin-Coated Hydrophobic Hemostatic Zeolite Gauze for Rapid Coagulation with Minimal Adhesion. | LitMetric

Paraffin-Coated Hydrophobic Hemostatic Zeolite Gauze for Rapid Coagulation with Minimal Adhesion.

ACS Appl Mater Interfaces

Key Lab of Applied Chemistry of Zhejiang Province, Department of Chemistry, Zhejiang University, Hangzhou 310027, China.

Published: November 2021

To solve the problem of strong adhesion and excessive blood loss caused by the use of hydrophilic zeolite gauze (Z-Gauze) in uncontrollable bleeding, we have modified the surface of commercial Z-Gauze with a paraffin coating and prepared a hydrophobic dressing PZ-Gauze. After paraffin coating, the adhesion of Z-Gauze was reduced without an obvious decrease in coagulation activity. The clotting time of the hydrophobic PZ-Gauze was reduced from 378.3 to 154.6 s compared with that of cotton gauze, and the peeling force was decreased from 348.8 to 84.7 mN compared with that of Z-Gauze. Besides, PZ-Gauze can efficiently cut down the blood loss during treatment. On the basis of in vitro and in vivo experiments, it is confirmed that surface hydrophobic modification does not change the procoagulant performance because of the maintained cation exchange capacity of zeolites, and the reduced blood loss as well as enhanced difficulty for fibrin adhesion is attributed to its hydrophobicity. This is different from the traditional gauze procoagulant theories, where gauze hydrophilicity and procoagulant performance are always positively correlated.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.1c10891DOI Listing

Publication Analysis

Top Keywords

blood loss
12
zeolite gauze
8
paraffin coating
8
procoagulant performance
8
gauze
5
paraffin-coated hydrophobic
4
hydrophobic hemostatic
4
hemostatic zeolite
4
gauze rapid
4
rapid coagulation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!